ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
  • ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
Find Similar Products
  • Overview
  • The working principle
  • Main technical features
  • Product Parameters
  • Full Set
  • Detailed Photos
  • Packaging & Shipping
  • Contact us
Overview

Basic Info.

Model NO.
GD-3536D
Usage
Automatic Coc Flash Point Tester
Apparatus
Automatic Cleveland Open Cup Flash Point Tester
Function
Automated Cleveland Open Cup Flash Point Apparatus
Application
Flash Point and Fire Point Test
Testees
Petroleum Products, Bituminous Materials
Measurement Range
Room Temperature~400c
Type
Fully Automatic
Overall Power Consumption
No More Than 500W
Reference Standard
ASTM D92, GB/T 3536, ISO 2592
Transport Package
Standard Wooden Case
Specification
ISO Certificate
Trademark
Gold
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
100sets/Month

Product Description

GD-3536D Automatic COC Flash Point Tester for Flammable Petroleum Products

The working principle

* Fill sample in the test cup and put the test cup on the heater to heat the sample. The flash point of the sample is the lowest liquid temperature at which application of the test flame causes the mixture of the sample vapors and air around the sample to appear flash .
* To determine the fire point, the test is continued until the application of the test flame causes the sample to ignition and sustain burning for a minimum of 5 s
* The Open Cup Flash Point Tester Apparatus adopts SCM and electric circuit to form the signal collection, processing, output, and controlling system. The CPU will send orders to control the heater as per the temperature changes collected by the temperature sensor during working procedures, so that the sample temperature increases at a certain speed. The flame application interval, flame application time, and flash detection can be automatically controlled.
* Operation system will stop data-collection after the instrument detect the flash point automatically, and the flash point temperature will be locked on the LCD and printed out. If you need to determine the fire point, continue to heat the sample, the coverplate will rotate out automatically to cover sample cup for flameout after determining the fire point and sustain burning for a minimum of 5 s, then the test arm is automatically raised up, the test ends

Main technical features

ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
1. The Automatic COC Flash Point Tester adopts colored LCD screen, man machine conversation interface, and blank
buttons. It can preset expected temperature, sample ID, barometric pressure, test date and other parameters. It has menu prompts and input guide.
2. It can simulate and show temperature-time curve. It has prompt function to modify operation
error. It also has prompt function for test data, test time and other parameters.
3. It can correct the effect of barometric pressure to test and calculate the modified value.
4. Differential detection; the system error can be automatically modified.
5. It can complete flame application, flash detection, and data printing automatically. The test arm can be raised up and lowered down automatically.
6. Electronic ignition, forced air cooling (Note: manual igniting button is located on the left side of instrument );

 

Product Parameters

1 Power supply AC ( 220±10% ) V, 50Hz
2 Temperature measurement Range : room temperature ~ 400 °C
Repeatability :≤ 8 °C
Reproducibility :≤ 17 °C
Accuracy : 0.1 °C
3 Heating rate Correspond with GB/T3536 and ASTM D92
4 Igniting mode Electric ignition 
Gas flame diameter: 3.2mm ~ 4.8mm
5 Ambient temperature (10 ~ 40) °C
6 Relative humidity ≤ 80%
7 Maximum power consumption 500W
8 Dimension 520mm×380mm×310mm      
9 Weight 13kg

 

Full Set

No. Name Unit Quantity Remark
1 Main unit Set 1  
2 Cleveland oil cup Piece 1 We can provide more if you required.
3 Ignition device Set 1  
4 Thermometer Piece 1 -6°C~400 °C, graduated scale is 2 °C
5 Thermometer support Set 1  
6 Power supply wire (250 V 6 A) Piece 1  
7 Fuse 5 A (Φ5×20) Piece 2  
8 Latex tube Φ6 Meter 1.5 Could not be used as coal gas tube
9 Joint for coal gas tube Piece 1 Connect coal gas tube and latex tube
10 Extinguishing cover  Piece 1  

Detailed Photos

ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
* GD-3536D Fully-Automatic COC Flash Point Tester has a lot of stocks

* It adopts open, fuzzy controlled integration software, and modular structure. It is advanced, friendly, convenient and accurate. It is the best choice of similar instruments. It has been widely used for flash point determination in the field of railway, aviation, power plant, petroleum industry, college and universities, scientific research institutes, and inspection department.



 
ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus

Packaging & Shipping

Our ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus product packaging has been proven over the long term and we usually have plywood boxes or cartons with trays. We will arrange the appropriate packaging according to the weight and size of the goods. Of course, you can also choose the packaging form.

Contact us

If you are interested in our  ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus product or have any questions, please feel free to contact us.

ASTM D92 Cleveland Open Cup Flash Point Tester Apparatus
 
 
 
 
 
 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier