Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Tan Delta Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
  • Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
GDMZ
Type
Transformer Tan Delta Tester
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
28kg
Power Source
AC220V
Product Name
Transformer Tan Delta Tester
High Voltage Output
0.5~10kv
Accuracy 1
Tg: ± (Reading *1.5% +0.06%);
Measuring Range
0.001% <Tg <100%
Accuracy 2
Cx: ± (Reading * 1.5% +5 PF)
Harmonic Adaptation
≤ 3%
Power Supply
AC 220V ± 10% 50/60 ± 1Hz
High Voltage Output 1
Increasing by 500V for Each Level, a Total of 20 L
Transport Package
Plywood Case
Specification
465*350*360mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

10KV/12 KV Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter
 
Product Description

 

Power Transformer Tan Delta Tester Capacitance Dielectric Loss &amp; Dissipation Factor Meter
Power Transformer Tan Delta Tester Capacitance Dielectric Loss &amp; Dissipation Factor Meter

 

  1. Power Transformer Tan Delta Tester is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipment in the power plants and substations. The adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.
  2. The operation instruction of the instrument is English. The whole process is measured automatically through microcomputer.
  3. The instrument also applies to the measurement of tgδ and electrical capacity of high voltage electrical equipment in the workshops, laboratories and research institutes.
  4. 10KV Power Transformer Tan Delta Tester Capacitance Dielectric Loss & Dissipation Factor Meter with Micro Printer could measure non-grounded or grounded high voltage equipment adopting positive and negative connection method. Besides, it could measure the tgδ of capacitor voltage transformer and capacitance of main capacitor C1and C2.
  5. 10KV China Digital Power Transformer Tan Delta and Capacitance Dielectric Loss & Dissipation Factor Tester with Micro Printer is equipped with high voltage step-up transformer. Besides, it takes security measures like zero-cross closing, lightning protection, etc. During the experiment, different levels of high voltage ranging from 0.5KV to 10kV are outputted. The instrument has the advantages of convenient and safe operation.
  6. Under the circumstance of oil dielectric loss ≥ 0.01%, with oil cup, positive wiring can be used to measure the dielectric loss of oil.

 

This following protection features are not included in this instrument:

• High voltage short-circuit protection

• CVT over-voltage protection

• Poor grounding protection


Technical Index
 

High voltage output

0.5~10kV

Increasing by 500V for each level, a total of 20 levels, capacity: 1500VA

Accuracy

tgδ: ± (reading *1.5% +0.06%)

Cx: ± (reading * 1.5% +5 PF)

Resolution

tgδ: 0.001%   Cx: 0.001pF

Measuring range

0.001% 100%;

Internal high pressure : 3PF ~60000PF/10KV,    60PF~1µF/0.5KV

External high pressure: 3PF ~1.5µF/10KV,       60PF~30µF/0.5KV

 

CVT Variable ratio test

Variation ratio measurement accuracy: ± reading *1%

The range of the measurement: 10~99999

Phase measurement accuracy: ±0.1°

Phase measurement range: 0~359.9°

Power supply  AC 220V ± 10%   50/60 ± 1Hz
 

Measuring method

a.single frequency: 45(45Hz measuring),50(50Hz measuring),55(55Hz measuring),
                                60(60Hz measuring),65(65Hz measuring)

b.different frequency: 50D(45Hz/55Hz measure each time);

                                   60D(55Hz/65Hz measure each time);                                                                Automatic frequency conversion

Harmonic adaptation  ≤ 3%
Application condition  -15 ºC-50 ºC Relative humidity <80%
Dimension  460 (L) * 345 (W)* 345 (H)

Weight

30 kg



10KV High Voltage Output
Power Transformer Tan Delta Tester Capacitance Dielectric Loss &amp; Dissipation Factor Meter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier