• Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
  • Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
  • Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
  • Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
  • Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
  • Cheap Price CT Analyzer Current Transformer Tester CT PT Tester

Cheap Price CT Analyzer Current Transformer Tester CT PT Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Current Transformer Tester CT PT Tester
Product Name: Current Transformer Tester CT PT Tester
Usage: Transformer Tester
Test Standards: IEC60044-1/2/5/6
Voltage Output: 0.1~180V (AC)
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDVA-405
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Cheap Price CT Analyzer Current Transformer Tester CT PT Tester


Cheap Price CT Analyzer Current Transformer Tester CT PT Tester

A Transformer CT PT Tester, also known as a Current Transformer Potential Transformer Tester or CT PT Analyzer, is a specialized instrument used to test and analyze the performance of current transformers (CTs) and potential transformers (PTs).
 

  1. Turns Ratio Test: The tester can measure the turns ratio of CTs and PTs, which is the ratio of the primary to secondary windings' turns. This test helps verify if the transformers are correctly designed and providing accurate current or voltage transformation.

  2. Polarity Test: The tester verifies the polarity of the transformer windings to ensure they are connected correctly. Proper polarity is essential for accurate measurement and coordination with protective relays.

  3. Ratio Error Test: This test determines the accuracy of the transformers by comparing the measured ratio to the rated ratio. Any deviation from the expected ratio can indicate a fault or degradation in the transformers' performance.

  4. Excitation Curve Test: The tester measures the magnetization characteristics of the CTs and PTs by applying different voltages and recording the resulting currents. This test helps evaluate the saturation behavior and linearity of the transformers.

  5. Burden Test: The tester measures the burden impedance of the CTs and PTs to ensure they fall within the specified limits. Burden impedance affects the accuracy and performance of the transformers under different load conditions.

  6. Winding Resistance Test: The tester measures the resistance of the transformer windings to assess their condition and detect any potential faults like loose connections or high resistance joints.

  7. Saturation Test: The tester checks the saturation characteristics of the transformers by applying increasing voltages until saturation occurs. This test helps determine the transformers' operating limits and performance under high-magnitude current or voltage conditions.

  8. Demagnetization: The tester can perform a demagnetization process to remove any residual magnetism in the transformers.
     

Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
Cheap Price CT Analyzer Current Transformer Tester CT PT Tester

 

GDVA-405 CT PT Analyzer
1 Test standards IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Gross Size 70*50*41CM
21 Gross Weight 40kg


Standard configuration for CT/PT Analyzer:

Name  Quantity  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  

Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
Cheap Price CT Analyzer Current Transformer Tester CT PT Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters