Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year
Still deciding? Get samples of US$ 1350/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
  • Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
  • Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
  • Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
Find Similar Products

Basic Info.

Model NO.
GDBC-901
Application
Current Transformer Transformation Ratio Test
Function
Electrical Testing Equipment TTR Tester
Device
Automatic Turns Ratio Tester for Transformer
Ratio Measurement Range
1-10000
Group Measurement
1-12
Phase Measurement Error
1 Degree
Test Voltage
0~80V, Frequency 50Hz
Size
400mm*350mm*200 mm
Transport Package
Standard Wooden Case
Specification
ISO
Trademark
Gold
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
2000 PCS/Month

Product Description

GDBC-901 Automatic Transformer Transformation Turns Ratio Tester Megger

Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger


Introduction:
1.  GDBC-901 Automatic Transformer Transformation Turns Ratio Tester Megger is designed according IEC76-1 and IEC60044. 
2.  GDBC-901 Automatic Transformer Transformation Turns Ratio Tester Megger could be applied to test the ratio of single or three phase transformer. Also the connection group of three phase transformer could be calculated with the ratio. All parameters are measured in one test for three phase transformer. 


Functions:
1 The voltage ratio measurement for three or singe phase transformer
2 The group vector measurement for three phase transformer.
3 The polarity measurement for single phase transformer or CT/PT
4 Voltage ratio error calculation
5 Current transformer ratio measurement
6 Excitation current measurement in ratio testing
7 Reproduction the AC test voltage from power source to reduce the effects of bad power source
8 Save the test results in the memory internal the tester
9 Print the test results by micro printer
10 Reverse connection detect unit to prevent the high voltage injected to operator
11 Over current protection unit integrated in software and hardware
12 Upload the test results to PC by RS232 and make word report by software


Technique Indexs:
1 Ratio measurement range: 1-10000
2 Group measurement: 1-12
3 Phase measurement error: 1 degree
4 Ratio measurement error: 1-2000 ± 0.2%RDG   2000-10000  ± 0.5%RDG
5 Test voltage:0~80V, frequency 50Hz
6 Power supply: AC220V ± 10%, 50Hz/60Hz
7 Environment temperature: 0-50ºC
8 Humidity: ≤85%RH
9 Size 400mm´350mm´200 mm     Weight:7kg

Testing Progress:

Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
 
Packaging & Shipping:
When the meter need to ship, it is suggested to use plywood case and damping items, to avoid unnecessary damages, when there is no plywood case, it should not be stacked. In the shipping condition, the display screen is upward. The machine bottom should be placed on moisture proof. The machine should be placed in dry, free of dust, ventilate, no corrosive air.


Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger

Customer Visit
Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger

Customer Feedback
Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger

Exhibition

Gdbc-901 Automatic Transformer Transformation Turns Ratio Tester TTR Megger
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier