12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Tan Delta Test Set Ipf Tester
Still deciding? Get samples of US$ 2800/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
  • 12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
Find Similar Products

Basic Info.

Model NO.
GDGS
Type
Transformer Tan Delta Test Set Ipf Tester
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Weight
28kg
Power Source
AC220V
Usage
Tan Delta Test Set Ipf Tester
Application
Transformer Tangent Delta Test
Function
Transformer Dissipation Factor Test
High Voltage Output
0~2200vsmall Size, Portable, Automatic Dielectric
Definition
Tgδ: 0.001% Cx: 0.1PF
Maximum Current
140mA
Capacity
1000va
Use Conditions
-15ºC∽40ºC
Transport Package
Standard Wooden Case
Specification
55*49*58cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
2000PCS/ Month

Product Description


12kV Transformer Dielectric Loss Tester Tan Delta Test Set IPF Tester
 
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
 
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester

What is transforme IPF


The term "transformer IPF" refers to the "Impedance Voltage or Impedance Power Factor" of a transformer. It is a measure of the impedance of the transformer and is used to assess the transformer's ability to transfer power efficiently.

In a transformer, the impedance is primarily due to the resistance of the windings and the reactance caused by the inductance. The impedance voltage or power factor is a measure of the phase angle between the voltage and the current in the transformer's impedance. It indicates the degree of reactance in the transformer and can help evaluate the efficiency and performance of the transformer.

A high impedance power factor indicates a higher degree of reactance and can result in increased losses, reduced voltage regulation, and decreased efficiency. On the other hand, a low impedance power factor indicates lower reactance and better performance.

Transformer IPF is typically measured during routine testing or maintenance of the transformer. By monitoring the IPF over time, it is possible to detect any changes in the transformer's impedance and identify potential issues that may require further investigation or corrective actions.


Introduction
  • 12kV Transformer Dielectric Loss Tester Tan Delta Test Set IPF Tester is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

  • It can also supply high voltage source for testing.

  • Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

  • It can also use generator as power supply;

  • If equipped with a insulation oil vessel and a temperature detector, it can also measure tan delta of insulation oil;

Specifications:
  
No Item Name 10kv Automatic Transformer Dielectric Loss Tester Tan Delta Tester
1 Use conditions -15ºC∽40ºC RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10% Allowable generator
4 High output 0.5KV∽10KV Every 0.1kV
Precision 2%
Maximum current 200mA
Capacity 2000VA
5 Self-excited power AC 0V∽50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision △tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8 measuring range tgδ Unlimited
C x 15pF < Cx < 300nF  
10KV Cx < 60  nF
5KV Cx < 150 nF
1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT range 10∽10000  
  accuracy 0.1%  
  Resolving power 0.01  
10 Memory size The 200 group supports U disk data storage  
 
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester
12kv Transformer Dielectric Loss Tester Tan Delta Test Set Ipf Tester

 