  • En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
  • En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
  • En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
  • En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
Find Similar Products

Basic Info.

Model NO.
GD-ISO9239
Standard
ISO 9239-1; ISO 9239-2; ASTM E648; ASTM E970
Utilities
Bottled Propane Gas, Air Compressor
K-Type Thermocouples
Range, Ambient About 1500 Degree Centigrade
Sample Holder
Stainless Steel
Dummy Calibration Panel Holder
for Measuring Heat Fluxmeter
Pyrometer
for Measuring Radiant Panel Temperature
Exhaust
30~85 M3/Min
Instructions
Provide
Weight
About 300kg
Power
AC 220V, 50/60Hz, 20A
Console Size
600mm(W)* 750mm(D)* 1600mm(H)
Sliding Platform
for Loading The Specimen
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus


En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus

Introduction:

According to ISO9239-1,2 and GB/T 11785-2005 requirements, University Radiant Test Panel Flammability Analyzer For Flooring Materials is measuring the critical radiant of combustion floor coverings, through the radiation environment of test chamber. It is can also be used to measure the critical radiation of the cellulose insulation floor material.

Specimen is located at down horizon of 30 degree sloped gas radiation panel per horizon surface. Pilot flame as ignition resource put a part edge of specimen on high temperature side.

University Radiant Test Panel Flammability Analyzer For Flooring Materials record ignition time by spark, moving time which flame horizontal pass by specimen of length.

 

Application:

1.Building Materials

2.Rail

3.Automotive Interior

4.Other

 

Standard:

ISO 9239-1 Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source
ISO 9239-2 Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2
 ASTM E 648 Standard Test Method for Critical Radiant Flux of Floor- Covering System Using a Radiant Heat Energy Source
ASTM E 970 Standard Test Method for Critical Radiant Flux of Exposed at Attic Flooring Insulation Using a Radiant Heat Energy Source
NFP A 253 Standard Method of Test for Critical Radiant Flux of Floor Covering System Using a Radiant Heat Energy Source (National Fire Code. Vol.6)
KS F ISO 9239- 1 Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source
KS F ISO 9239- 2 Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2

 

Product Pictures:
En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus

En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
 

Main Features:

1. All structural components are made of stainless steel, beautiful appearance and corrosion resistance.

2. The test chamber is made of the panel (calcium + silicate ) as 13±1 mm of thickness and 650 kg/m3 of nominal density.

3. Air pass dimension between the test chamber and test specimen holder is produced by (0.23±0.03) m3 at both beside of specimen fairly.

4. The calorimeter is imported from the United States, range 50kW/m2.

5. The radiant chamber had a stop of 30±1degree per horizon panel and can be resisted up to 900-degree centigrade. It also should be included in the safety-blocking function.

6. The radiation source is a porous ceramic heat radiating plate of 300mm*450mm and tilted 30 °.

7. The pilot burner should be stationed equally as 0.7mm diameter and 19/EA produced a slop of 60 degrees per centre line bottom.

8. Air velocity of exhaust stack should be attached an exhauster as 2.5±0.2 m/s.

9. It should be used a radiation pyrometer which can be monitor 250mm diameter from about 1.4 meters and has ±5 degree centigrade sod ml accessory with 480ºC to 530ºC (black body temperature) range for adjustment the surface quality of heat of radiant panel.

10. It can be measured hat flow within tolerance from radiant heat panel to 110mm to 910mm at 100mm intervals.

 

Specification:

Product Name En ISO 9239-1, ASTM E648 Radiant Flooring Panel Apparatus
Steel frame chamber, Dimension 1,400mm(W)×500mm(D)×2,200mm(H)
Console Size 600mm(W)×750mm(D)×1600mm(H)
 Power AC 220V, 50/60Hz, 20A
Weight  about 300kg
Instructions  Provide
Exhaust 30~85m3/min
 K-type thermocouple Range, Ambient about 1500 degree centigrade
 Utilities Bottled propane gas, Air compressor (5HP)