• Class 0.2 Transformer Load and No-Load Tester
  • Class 0.2 Transformer Load and No-Load Tester
  • Class 0.2 Transformer Load and No-Load Tester
  • Class 0.2 Transformer Load and No-Load Tester
  • Class 0.2 Transformer Load and No-Load Tester

Class 0.2 Transformer Load and No-Load Tester

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year
Usage: Transformer on-Load Tap-Changer Tester
Setting Sample Rate: 10~20kHz
Maximum Output Current: 0.5A
Power Supply: 220V 50Hz
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
GDBR-P
Test Object
Power Transformer and Special Transformer
Application
Measure Loading Tap Switch Property Index of Power
Features
It Is Controlled by Computer
Product Name
Transformer on-Load Tap-Changer Tester Test Set
Transport Package
Wooden Case
Specification
20KG
Trademark
Gold
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month

Product Description

Class 0.2 Transformer Load and No-Load Tester

Class 0.2 Transformer Load and No-Load Tester
Introduction:

Class 0.2 Transformer Load and No-Load Tester can measure the voltage, short circuit current, no-load loss, and short circuit (load) loss of a transformer. It is possible to conduct harmonic tests and analyze the 31 harmonics. The instrument shifts ranges automatically, enabling voltage measurement, a large current range, and straightforward wiring. Test the three-phase transformer under load and at no load to see if the wiring is proper. The instrument will also show the three-phase voltage and current vector.

One tester is all that is required to measure the load experiment under a 1600 kVA distribution transformer at full current; however, under 2500 kVA distribution transformers, the measurement can be completed in 1/3 of the rated current (in this case, the instrument can be used to calculate the load loss parameters under the rated current). Automatic corrections are made to all test results. Automatic corrections are made to all test results. The instrument has a wide range of correction capabilities, including waveform correction, temperature correction, non-rated voltage correction, non-rated current correction, and others.

Feature:

♦ It can assess the transformer's short circuit voltage, short circuit (load) loss, no-load current, and no-load loss;

♦ It is possible to conduct a harmonic test and analyze the 31 harmonic;

♦ The instrument shifts the range automatically, enabling voltage measurement, broad current range, and straightforward wiring;

♦ Perform a three-phase transformer no-load, load test; the instrument will show the three-phase voltage and current vector and will automatically decide whether the wiring is proper;

♦ Under 1000 KVA distribution transformers, the load experiment can be measured at full current; under 3150 KVA distribution transformers, it can be measured at 1/3 of the rated current (the instrument can be converted to the load loss parameters at the rated current);

♦ Automatic corrections are made to all test results. The device has a wide range of correction capabilities, including waveform correction, temperature correction, non-rated voltage correction, non-rated current correction, and more;

♦ LCD with a big screen of 320 * 240 pixels, high brightness display, comprehensive menu, and quick operation in English characters to actualize man-machine conversation; touch button for easier operation; LCD with a broad temperature range and brightness adjustment;

Main Test Items:

  • RMS of three phase voltage: Uab,Ubc,Uca.

  • Average value of three phase AC voltage: Uab,Ubc,Uca.

  • RMS of three phase current: Ia,Ib,Ic.

  • Percentage of No-load loss and No-load current: Po,Io%.

  • Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.

  • Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.

  • Transformer actual capacity and judged capacity.

Technical Parameters Class 0.2 Transformer Load and No-Load Tester:

Current measurement range 100mA-60A accuracy: class 0.2.
Voltage measurement range 10V-650V accuracy: class 0.2.
External transformer can broaden the measurement range of instrument.
Frequency measurement range 40-65Hz accuracy: class 0.2.
Internal source Current output 0-10A
Voltage measurement 0-10V
Capacity Test 30kVA-2500kVA (for 10kV oil and dry transformers)
50kVA-31500kVA (for 35kV oil transformers)
50kVA-2500kVA (for 20kV dry transformers)
50kVA-2000kVA (for 35kV dry transformers)
     

Class 0.2 Transformer Load and No-Load Tester
Company Profile

Class 0.2 Transformer Load and No-Load TesterClass 0.2 Transformer Load and No-Load TesterClass 0.2 Transformer Load and No-Load Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters