Customization: | Available |
---|---|
Warranty: | 1 Year |
Power Supply: | AC 220V, 50/60Hz, 30A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Working Principle
Conical heater-rated power | 230V, 5000W; Heat output:0-120kw/m2 |
Touch screen size | 19" |
Operation | Automatic ignition, automatic timing, automatic gas quenching, and other functions, with the test online camera function, the whole process of combustion test camera. |
Temperature control | 3 Class K thermocouples and Phase 3 PID temperature controller |
Igniter | The 10kV spark igniter is fitted with a safe ceasefire device. |
Sample size | 100mm*100mm, Thickness≤50mm |
Filtration accuracy(Three stage filter) | 0.5um |
Sampling device | Has 12 holes in the opposite direction of the flow; a Built-in smoke filter; 685mm away from the smoke hood; |
Paramagnetic oxygen analyzer | Measurement range: 0-25% |
Error limit:<0.01% | |
Response time: :≤ 4s | |
Repeatability: <0.01% | |
Exhaust system | It is composed of the fan, fume hood, exhaust pipe, and orifice flow-meter |
American Sorebo Laser System | Smoke density accuracy error: 2%;Use photodiode, 0.5mW He-Ne laser;main and spare photodetector |
Temperature control system | American Omega thermocouple, precision 0.1ºC |
Micro pressure differential sensor | Imported from the United States; Accuracy: ±1%FS |
Hysteresis ±0.1%FS | |
Metherm thermoelectric reactor heat flow meter | Imported from the United States |
Equipped with water cooling system, safe protection of heat flow meter | |
Repeatability: ±0.5% | |
Range of 0~120kW/m2 | |
Accuracy : 3%,;repeatability:0.5%; | |
Japan Kofloc flow controller | Accuracy 2% |
ISO 5660 Reaction to fire tests - Heat release, smoke production, and mass loss rate
ASTM E 1354 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
BS 476 Pt.15 Fire tests on building materials and structures - Method for measuring the rate of heat release of products
GB/T 16172-2007 Test method for the heat release rate of building materials
NFPA 264 Method Of Test For Heat And Visible Smoke Release For Materials And Products Using An Oxygen Consumption Calorimeter
Fire test equipment applies to building materials, lithium batteries, aviation, rails, IMO, wire & cable, safety protection, etc.
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd was established in 2009. Now, it has developed 70 kinds of fire testing instruments and served for many industries such as building materials,lithium battery, aviation, rails, IMO, wire & cable, safety protection and so on. Our mission is to provide reliable products to our customers to meet their requirements of testing, R&D and quality control. In addition, Gold insists for high-quality standard in niche markets and targets to minimize the gap between Chinese local products and imported products. We work with trust, honesty and a sense of responsibility, so the quality and service are always our advantages among all competitors.