• Portable Transformer CT PT Test Set TTR Tester
  • Portable Transformer CT PT Test Set TTR Tester
  • Portable Transformer CT PT Test Set TTR Tester
  • Portable Transformer CT PT Test Set TTR Tester
  • Portable Transformer CT PT Test Set TTR Tester
  • Portable Transformer CT PT Test Set TTR Tester

Portable Transformer CT PT Test Set TTR Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer CT PT Test Set TTR Tester
Product Name: Portable Transformer CT PT Test Set TTR Tester
Test Standards: IEC60044-1/2/5/6
Power Supply: 220V 50Hz
Usage: Transformer Tester
Samples:
US$ 6800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDVA-405
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Portable Transformer CT PT Test Set TTR Tester
 

Portable Transformer CT PT Test Set TTR Tester
Portable Transformer CT PT Test Set TTR Tester


 

Portable Transformer CT PT Test Set TTR Tester
Portable Transformer CT PT Test Set TTR Tester

 

What is the difference between voltage and current testing in a CT PT Tester?
 

  • Voltage Testing: This involves testing the voltage across the transformer's windings. Voltage transformers, which are part of the PT (Power Transformer) category, are designed to measure and reduce high voltage values to a smaller, manageable level. They are connected in parallel with the circuit, meaning the full line voltage appears at both ends of the winding. The primary winding of a voltage transformer has many turns and carries the voltage to be measured, while the secondary winding has a small number of turns and is connected to the instrument or meter. Voltage transformers are crucial for ensuring that the voltage levels within the transformer and the connected circuit are within safe operating limits, preventing overvoltage conditions that could damage the transformer or other components.
  • Current Testing: This involves testing the current flowing through the transformer. Current transformers, which are part of the CT (Current Transformer) category, are designed to reduce high currents to a safer and easier-to-manage level. They are connected in series with the transmission line, meaning the entire line current flows through the winding. The primary winding of a current transformer has fewer turns and carries the current to be measured, while the secondary winding has a large number of turns and is connected to the current winding of the instrument. Current transformers are essential for monitoring the current flowing through the transformer, ensuring it is within the expected range and preventing overcurrent conditions that could lead to overheating or other electrical faults.


What is the purpose of a CT PT Tester?
 

The tester performs highly accurate burden-based CT and PT ratio and phase error measurements (0.02% accuracy), ensuring transformers operate within expected parameters - crucial for power system accuracy and reliability. It can conduct:

- Excitation measurements on protection class CTs for overcurrent protection
- Optional live CT testing with real-time data under load conditions (GDVA accessory)
- CT/PT secondary winding resistance and PT primary included measurements
- CT 1.6 kHz admittance test for impedance characteristics
- Simulated full load inductive PT testing on up to 2 windings
- CT/PT burden testing for maintaining accuracy
- CT/PT polarity checks for correct phase relationships
- Batch testing of metering CTs for efficiency
- Estimating CT class without nameplate
Portable Transformer CT PT Test Set TTR Tester



Specification of a CT PT Tester
 

GDVA-405 Portable Transformer CT PT Test Set TTR Tester
1 Test standards IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Size 70*50*41CM
21 Gross Weight 40kg


Similar Products
 

Portable Transformer CT PT Test Set TTR Tester
Portable Transformer CT PT Test Set TTR Tester


GDVA-402 Transformer CT PT Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters