After-sales Service: | Lifetime Technical Support |
---|---|
Warranty: | 1 Year for Three Phase Overcurrent Relay Tester |
Type: | Secondary Injection Tester |
Accuracy Grade: | 1 |
Load Way: | Electronic Load |
Loading Method: | Dynamic Load |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Secondary injection tests are always done prior to primary injection tests. The purpose of secondary injection testing is to prove the correct operation of the protection scheme that is downstream from the inputs to the protection relay(s). Why done prior to primary injection tests? This is because the risks during initial testing to the LV side of the equipment under test are minimized.
Type of relay protection | Test items | Recommended test module | remarks |
Signal relay | Corresponding test items | DC test Intermediate relay DC test |
If the intermediate relay requires AC and DC mixed input, please test it in the "AC / DC test" module. If the rated current of the signal relay is too small, it can be tested by the voltage circuit output of the tester. |
Time relay | |||
Intermediate relay | |||
Reclosing relay | |||
Current relay | Corresponding test items | AC test Current voltage Inverse time current relay DC test |
The sequence component relay can be tested in the special sequence component module of "AC test". The inverse time relay can also be tested in "inverse time overcurrent". |
Over (under) voltage relay |
|||
Sequence component relay | |||
Synchronous check (or phase comparison) relay | |||
Inverse time current relay | |||
Differential relay | DC magnetization characteristics | Differential relay Differential test Harmonic test |
During the test, please refer to the wiring mode of "differential test" in the manual for correct wiring. |
Harmonic braking characteristics | |||
Proportional braking characteristics | Differential test Differential relay AC test |
||
Power (direction) relay |
Corresponding test items | Power direction AC test |
Before testing the power (direction) relay, the wiring type and the general action boundary of the protection should be determined in advance. |
Impedance relay | |||
Synchronizing relay | Corresponding test items | Simultaneous test AC test |
The UA and UB of the tester are used as the voltage output of the system side and the side to be paralleled respectively in the "synchronization test" module, which can measure the action frequency, action voltage and phase, and carry out automatic quasi synchronization test. |
Frequency relay | Corresponding test items | Frequency test |
It can be used to test the slip and closing frequency. |