Current Transformer Analyzer Transformer Turn Ratio Tester

After-sales Service: Life Time Support
Warranty: 1 Year for Transformer CT PT Tester
Type: Transformer CT PT Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Static Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDVA-405
Display
Digital
Control
Fully Automatic
Weight
15kg
Power Source
AC220V
Product Name
Current Power Transformer Tester CT PT Analyzer
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

GDVA-405 Current Transformer Analyzer Transformer Turn Ratio Tester

Current Transformer Analyzer Transformer Turn Ratio Tester

Current Transformer Analyzer Transformer Turn Ratio Tester

 

For Current Transformers:

1. The excitation characteristic curve and parameter values need to be determined through testing.    

2. The ratio of the number of turns in the primary and secondary windings must be measured.

3. Any ratio error or phase displacement error should be checked through tests. 

4. The polarity markings should be verified against the design.   

5. The resistance of the windings must be measured through testing.

6. The loading characteristics of the secondary loop need to be determined.

7. An error curve test is required for protection current transformers.      

8. The transient performance parameters should be measured through tests.   

9. An attempt should be made to deduce the nameplate specification through observation.   

10. The saturation hysteresis loop curve needs to be plotted through measurements.

For Potential Transformers:

1. The turns ratio needs to be measured through testing.

2. Testing is required to check for any ratio error or phase displacement error.   

3. A test must be conducted to ensure the polarity markings are correct.         

4. Testing is needed to determine the loading characteristics of the secondary winding.

5. The resistance of the windings should be measured through tests.
 

GDVA-405 CT PT Analyzer
1 Test standards IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Size 70*50*41CM
21 Weight 40kg
 

Detail Display:

Current Transformer Analyzer Transformer Turn Ratio Tester

Current Transformer Analyzer Transformer Turn Ratio Tester

 

Current Transformer Analyzer Transformer Turn Ratio Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters