High Precision Transformer Insulating Oil Dielectric Loss Oil Tangent Delta Analyzing Apparatus

Weight: 0-100Kg
Power Source: AC220V
Condition of Use: -5ºC-40ºC Rh<80%
Power Source: AC 220V±10% Without Frequency Limit
AC High Voltage Output: 400V-2200V ±2% Every 100V 50va
DC High Voltage Output: 0V-2200V ±2%
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGY
Temperature Control Induction Stove
Maximal Power 500W
Temperature Control Range
<100ºC
Temperature Measuring Error
±0.5ºC
Control Temperature Error
0.1ºC
Control Temperature Time
Room Temperature 90ºC <20min
Relative Dielectric Loss Constant
Er Calculated Automatically
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
China
Production Capacity
1000 Sets / Month

Product Description

High Precision Dielectric Loss oil tangent delta tester  transformer insulating oil loss analyzing apparatus

  • Introduction:
  1. GDGY Automatic Transformer Oil Tan Delta Tester is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc.
  2. The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.
  3. AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the instrument can operate correctly.
  4. The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and capacitance is not influenced by environmental temperature and dampness etc. In this way, the accuracy of the instrument is guaranteed conformably after a long-time application.
  • Specifications:
High Precision Dielectric Loss oil tangent delta tester  transformer insulating oil loss analyzing apparatus 
Item Name GDGY Automatic Transformer Oil Tan Delta Tester
Condition of Use -5ºC-40ºC RH<80%
Power Source AC 220V±10% Without Frequency Limit
AC High Voltage Output 400V-2200V ±2% Every 100V 50VA
DC High Voltage Output 00V-2200V ±2%
Temperature Control Induction Stove Maximal Power 500W
Temperature Control Range <100ºC
Temperature Measuring Error ±0.5ºC
Control Temperature Error 0.1ºC
Control Temperature Time Room Temperature 90ºC <20min
Measuring Range tgδ Without Limit
Cx 15PF-300PF
Rx 10M-10T
Resolution tgδ 0.001%
Cx 0.01pF
Rx 0.01
Precision delta tgδ:±(Reading*0.5%+0.020%)
delta Cx :±(Reading*0.5%+0.5PF)
delta Rx :±Reading * 10%
Relative Dielectric Loss Constant Εr Calculated Automatically
Volume Resistivity ρ Calculated Automatically
Dimension 450(L)×310(W)×360(H)
Net Weight 21KG
  • Product Show:
High Precision Transformer Insulating Oil Dielectric Loss Oil Tangent Delta Analyzing Apparatus
 