• Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
  • Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
  • Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
  • Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
  • Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
  • Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment

Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Turn Ratio Meter
Type: Transformer Turn Ratio Meter
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDBC-901
Display
Digital
Control
Manual Control
Weight
7kg
Power Source
AC220V
Product Name
Transformer Turn Ratio Meter
Standard
IEC76-1, IEC60044, GB/T1094
Test Voltage
0-80kv
Applicable to Transformer
Connected in Y Type, D Type
Ratio Measurement Range
1-10000
Group Measurement Range
1-12
Phase Measurement Error
1 Degree
Power Supply
220V 50Hz/60Hz
Turn Ratio Resolution
0.0001
Humidity
85%
Transport Package
Wooden Case
Specification
400*350*200mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment


Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment

Why is transformer turn ratio (TTR) test necessary?

Power transformer turns ratio test is an AC low voltage test which determines the ratio of the high voltage winding to all other windings at no-load. The turns ratio test is performed on all taps of every winding. 

The purpose is to check whether the number of turns of each winding, the assembly of lead wires, and the indication position of the tap changer meet the requirements.

The parallel operation of small and medium-sized transformers with a ratio difference of 1% will generate a circulating current of 10% of the rated current in the transformer windings, which will greatly increase the loss of the transformer and be detrimental to the operation of the transformer.


Features:

* GDBC-901 Three Phase Transformer Turns Ratio TTR Measuring Meter is designed according IEC76-1, IEC60044 and GB/T1094
The tester makes automatic measurement with no need to set any parameters and automatically completes the three-phase ratio and connection group measurements with easy operation.
* The tester measures three-phase and single-phase transformer ratios automatically, and calculates the ratio error.
* The tester can measure transformer connection group label and polarity to clearly display the first and second winding connection vector.
* GDBC series Transformer Turns Ratio TTR Meter is a professional testing equipment which is suitable for transformer manufacture, transformer service industry, substation maintenance, power transformer /distribution transformer maintenance company and other transformer testing field.



Specification:

Ratio measurement range 1~10000
Group measurement 1~12
Phase measurement error 1 degree
Ratio measurement error 1~2000: ± 0.2%RDG; 2000~10000: ± 0.5%RDG
Test Voltage up to 80kV
Power supply AC220V ± 10%, 50/60Hz
Humidity ≤85%RH
Size 58*45*36CM
Net weight 22kg



GDBC-901 Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment Display:
Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment
 

Testing Process:

Transformer Turn Ratio Meter Turns Ratio Tester TTR Testing Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters