• High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter

High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Tan Delta Power Factor Meter
Type: Tan Delta Power Factor Meter
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Static Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Item Detail
  • Success Cases
Overview

Basic Info.

Model NO.
GDGS
Display
Digital
Control
Manual Control
Weight
28kg
Power Source
AC220V
Product Name
Transformer Tan Delta Power Factor Meter
Internal Hv
0.5~10kv
Power Supply
AC220V±10 % 50Hz/60Hz
Input Current Range
10μa~1A
Condition of Use
-5°c~40°c, Rh<80%
Frequency of Self-Excited Power
45Hz /55Hz
Maximum Current of Self-Excited Power
15A
Maximum Output Capacity
200mA
Transport Package
Standard Wooden Case
Specification
55*49*58cm
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
50PCS/Month

Product Description

High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter


 

Product Description

High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

  • It can also supply high voltage source for testing;

  • Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

  • High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter can also use generator as power supply;

  • If equipped with a insulation oil vessel and a temperature detector, it can also measure tan delta of insulation oil.

 

Product Parameters

 

No. Item Name High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter 
1 Use conditions -15ºC∽40ºC RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10% Allowable generator
4 High output 0.5KV∽10KV Every 0.1kV
    Precision 2%
    Maximum current   200mA
    Capacity 2000VA
5 Self-excited power AC 0V∽50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision △tgδ:±(Reading*1.0%+0.040%)
    △C x :±(Reading*1.0%+1.00PF)
8 measuring range tgδ Unlimited
    C x 15pF < Cx < 300nF
      10KV Cx < 60  nF
       5KV Cx < 150 nF
       1KV Cx < 300 nF
    CVT test Cx < 300 nF
9 CVT range 10∽10000  
  accuracy 0.1%  
  Resolving power 0.01  
10 Exterior dimension 350(L)×270(W)×270(H)  
11 Memory size The 200 group supports U disk data storage  
12 Weight 28 Kg  
 

Item Detail

 

High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter
 

Success Cases

High Quality Dielectric Loss Tester Transformer Tan Delta Power Factor Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters