• 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
  • 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
  • 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
  • 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
  • 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
  • 0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester

0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Vlf AC Hipot Tester
Input: 220 ± 10% Volts AC, 50/60 Hz, Single Phase.
Output-Voltage: 80kv
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz
Stability of Frequency: Fluctuation < 0.5%
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
VLF AC Hipot Tester
Measurement Accuracy
± 3%.
Voltage Waveform Distortion
≤ 5%
Construction
in Two Units: Controller and Booster.
Ambient Conditions of Use
-10ºC to + 50ºC
Humidity
≤ 85%
Transport Package
Standard Wooden Case
Specification
50kg
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
500PCS/Month

Product Description

0.02Hz 30KV to 80KV VLF Very Low Frequency AC Hipot Tester 

0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester

Product Description

 

  • VLF Tester is designed and manufactured for electrical equipment very low frequency withstand voltage test.

  • Very low frequency withstand voltage test is essentially an alternative of power frequency withstand voltage test. It is much smaller, lighter and portable than power frequency withstand voltage tester. It is proved home and abroad that 0.1Hz ultra-low frequency withstand voltage test can replace power frequency withstand voltage test.

  • It can be applied for 10kV, 35kV, 300MW thermal power machine, 10kV, 35kV power transformer and other electrical equipment

 

Specifications:

  • Max voltage output: refer to following table;

  • Output frequency: 0.1Hz, 0.05Hz, 0.02Hz;

  • Measurement accuracy: 2.5%;

  • Positive and negative voltage peak errors < 2.5%RDG+0.3%FS;

  • Voltage wave form distortion:<3%;

  • Insulation resistance measurement error:<2.5%;

  • Leakage current measurement error:<2.5%;

  • Power supply:AC220V ± 10%, 50Hz/60Hz;

  • Environment temperature: 0~50°C;

  • Humidity:≤85%RH;

  • Model

    Rated Voltage/current

    Load Carrying

    Capacity

    Power fuse wire

    Product Structure and Weight

    30

    30kV/20mA

    (Peak)

    0.1Hz,≤0.5µF~1.1µF

    5A

    Controller:4kg

    Booster: 25kg

    0.05Hz,≤0.5µF~2.2µF

    0.02Hz,≤0.5µF~5.5µF

    50

    50kV/30mA

    (Peak)

    0.1Hz,≤0.5µF~1.1µF

    7A

    Controller:4kg

    Booster: 50kg

    0.05Hz,≤0.5µF~2.2µF

    0.02Hz,≤0.5µF~5.5µF

    60

    60kV/30mA

    (Peak)

    0.1Hz,≤0.5µF

    9A

    Controller:4kg

    Booster Grade 1(30kV):25kg

    Booster Grade 2(30kV):25kg

    0.05Hz,≤0.5µF~1µF

    0.02Hz,≤0.5µF~2.5µF

    80

    80kV/30mA

    (Peak)

    0.1Hz,≤0.5µF

    12A

    Controller:4kg

    Booster Grade 1(30kV):25kg

    Booster Grade 2(50kV):50kg

    0.05Hz,≤0.5µF~1µF

    0.02Hz,≤0.5µF~2.5µF

 

Features:

  • Data of current, voltage and wave form can be directly sampled at high voltage side, so the data is real and accurate;

  • Over-voltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself; the actuation time is less than 15ms;

  • Over-current protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 15ms;

  • A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside;

  • As a result of high and low voltage closed-loop negative feedback control circuit, the output without capacitive rise effect;

  • High-voltage control part adopts innovative light control HV switching unit, control is accurate, safe and reliable;

  • With color man-machine interface touch control plus controls modular software operating system, precise and intuitive;

  • Multi-purpose, can simultaneously measure tested objects capacitance, insulation resistance, leakage current, and AC withstand voltage test;

    Spare Parts:

    0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester
     

Training VLF-60KV Hipot Tester for Thai Customers:

0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester0.02Hz 30kv to 80kv Vlf Very Low Frequency High Voltage AC Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters