• High Voltage Circuit Breaker Mechanical Characteristic Tester
  • High Voltage Circuit Breaker Mechanical Characteristic Tester
  • High Voltage Circuit Breaker Mechanical Characteristic Tester
  • High Voltage Circuit Breaker Mechanical Characteristic Tester
  • High Voltage Circuit Breaker Mechanical Characteristic Tester
  • High Voltage Circuit Breaker Mechanical Characteristic Tester

High Voltage Circuit Breaker Mechanical Characteristic Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Circuit Breaker Test Machine
Type: Circuit Breaker Test Machine Circuit Parameter
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 3500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGK-307
Display
Digital
Control
Manual Control
Weight
10kg
Power Source
AC220V
Production Name
Circuit Breaker Mechanical Characteristic Tester
Test Standard
IEC62271
Application
Circuit Breaker Analyzer
Applicable Circuit Breakers
Indoors, Outdoors, Vacuum and Sf6 Circuit Breaker
DC Power out
DC30V~250V/20A (Instantaneous)
Print
Mic-Printer
Speed Measurement
0~20m/S
Travel Range
600mm
Travel Resolution
1mm
Transport Package
Veneer Case
Specification
360*280*300mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

High Voltage Circuit Breaker Mechanical Characteristic Tester

High Voltage Circuit Breaker Mechanical Characteristic Tester

Introduction

A circuit breaker analyzer is an instrument used to check and evaluate the function of a circuit breaker to ensure the safety and reliability of its operation in an electrical system. It is usually used for parameter detection and analysis of AC high-voltage switches such as AC high-voltage circuit breakers, load switches, and disconnectors.
 

Advantages

(1) The analyzer integrates a vibration test function, providing a new method for testing the mechanical characteristics of circuit breakers, which is simpler and more effective.
(2) The test results contain more information about the circuit breaker. For circuit breakers with potential failure risks or failures, the cause of the failure can be quickly located.
(3) There is no need to change the original wiring connection method of the circuit breaker to achieve live detection of the mechanical characteristics of the circuit breaker.
(4) The arc extinguishing contact analysis module allows users to automatically evaluate the wear degree of the arc extinguishing contacts inside the circuit breaker without disassembling the circuit breaker.
(5) The circuit breaker circuit resistance measurement can be completed with the instrument alone, and users do not need to purchase a separate circuit resistance tester, which reduces the weight of the on-site test instrument and saves user costs.

Index

12 channels for 
time measurement
3-channel supports both the time contact and resistance contact time
6-channel isolated contacts for cascaded unit measurement of pole
Time measurement Range: 4000ms
Error :< 0.1ms
Resolution: 0.01ms
Linear resistance sensor: 
Travel measurement 
according to sensor
Linear resistance sensor
Measurement range: 0~250mm; resolution: 0.01mm; error:<0.5mm
Measurement range: 0~25mm; resolution: 0.01mm; error:<0.05mm
Angle resistance sensor:
Measurement range: 0~360°; resolution: 0.01°; error:<0.5°
Pre-insertion Resistance 
Measurement
Range: 50~5000ohm; error :<1%RDG+2D
Dynamic resistance 
measurement
Test current: 25~100A
Measurement error :< 1%RDG+2D
Contact resistance 
measurement
Range:0--10mohm ; Error<0.5%RDG+0.05%FS
Range: 0-2mohm; Error:<0.5%RDG+2D
Speed measurement 250mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D
25mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D
Angle sensor: 0~20m/s; error:<0.5%RDG+2D
Acceleration sensor: 0~20m/s; error:<5%RDG+2D
Coil current measurement Range: 0~20A; resolution: 0.001A; error:<0.01A
Vibration measurement Range: 0~5000G; error:<3%
Internal DC power source Voltage: 12~265V; current:0~20A
Data Save Built-in 8G storage memory and 2 USB interface for data export and 
external keyboard or mouse connection
Power supply AC220V±10%; 50Hz±10%
Working environment Temperature: -10~50°C; Humidity:<80%


On site use
High Voltage Circuit Breaker Mechanical Characteristic Tester
Photo Details

High Voltage Circuit Breaker Mechanical Characteristic Tester
High Voltage Circuit Breaker Mechanical Characteristic Tester
High Voltage Circuit Breaker Mechanical Characteristic Tester


High Voltage Circuit Breaker Mechanical Characteristic Tester


Accessories
High Voltage Circuit Breaker Mechanical Characteristic TesterHigh Voltage Circuit Breaker Mechanical Characteristic Tester
Why do we need to test circuit breakers regularly?


When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit
breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur.The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.
Given that circuit breakers may be inactive for months or even years prior to a fault, a regime of circuit breaker testing is an important safety factor. Proper functionality of a breaker is reliant on a number of individual components that have to be calibrated and tested at regular intervals to ensure the complete and successful breaking of the circuit when triggered. Poorly maintained circuit breakers may not activate after receiving the trigger signal sent by the protective.


High Voltage Circuit Breaker Mechanical Characteristic Tester
High Voltage Circuit Breaker Mechanical Characteristic Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now