  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
  • Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
Find Similar Products

Basic Info.

Model NO.
GDJB-PC6
Control
Manual Control
Power Source
AC220V
Product Name
Six Phase Secondary Injection Tester Relay Test
Usage
Secondary Injection Testing
Application
Relay Tester
Power
Electronic, AC220V±10% 50Hz
Function
6 Phase Relay Protection Tester
Current Channels
Standard 6 Phase
Voltage Channels
Standard 6 Phase
AC Current Output Range
30A/Phase or 180A (6 Phase)
DC Current Output Range
DC 10A/ Phase
Transport Package
Standard Venner Case
Specification
455× 530× 220mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
1000PCS/Month

Product Description

Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester

Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
Introduction:

The six-phase relay protection tester can complete the test of various relay protection devices. It is compact, accurate and user-friendly. It combines advanced technology with portability to achieve efficient relay testing.

Features:

Embedded within the system is a host computer paired with a large, programmable CPLD, offering enhanced flexibility and functionality.

The device is capable of handling up to 12 D/A outputs simultaneously, fulfilling a wide array of field testing requirements. Powered by a digital signal processor and a microcomputer, it is equipped to test traditional relays and protectors, as well as modern microcomputer-based relays, with particular suitability for transformer differential protection and conversion equipment.

The primary control board features a DSP+FPGA architecture, with a 16-bit DAC output, generating a high-density fundamental wave sine wave of 2000 points per cycle, significantly enhancing waveform quality and the precision of the testing equipment.

It utilizes a high-fidelity linear amplifier, ensuring the accuracy of low currents and the stability of high currents. The high-precision linear power amplifier supports 6 channels of voltage and 6 channels of current output.

An 8-inch LCD display is included, along with connectivity options such as a keyboard/mouse port, two USB ports, and two RS232 ports, enabling communication with PCs and other communication devices.

The system incorporates intelligent self-protection features. It also provides 8 channels of switch inputs and 4 channels of switch outputs, with input contacts that can be either empty or have a potential of 0-250V, featuring intelligent identification.

The equipment is rich in binary options and is supported by robust software functionalities.

More details:
Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester
Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester

Specifications:
 

Main Parameters

Current Channels

Standard 6 Phase

Voltage Channels

Standard 6 Phase

AC Current output range

30A/Phase or 180A (6 Phase)

DC Current output range

DC 10A/ Phase

AC Voltage output range

AC 120V/ Phase

DC Voltage output range

DC 160V/ Phase

AC current source

 

Output Accuracy

 

0.2%

6 phase current output per phase output (effective value)

0~30A

3 phase current output per phase output (effective value) 0~30A

6 phase in parallel max output

180A

Phase current values allowed to work a long time

10A

 

Phase current Max output power

300VA/phase

6 phase in parallel max output power

1000VA

6 phase in parallel current max output allowable working time

10s

Frequency range

 

20~1000Hz;

accuracy: 0.001Hz

 

 

Harmonic times

2~20; phase :0~360°;

accuracy: 0.1°

 

DC current source

Output Current

 

0~±10A /phase

Maximum output load voltage

20V

Accuracy

0.2%

 

AC voltage source

 

Output Accuracy

 

0.2%

 

Phase voltage output (effective value)

 

0~120V

Phase voltage / Line voltage output power

80VA/100VA

Line voltage output (effective value)

0~240V

Frequency range

20~1000Hz

Harmonic Times

1~20

 

DC voltage source

Phase voltage output range

0~±160V 

Accuracy

0.2%

Line voltage output range

0~±320V

Phase voltage / Line voltage output power

70VA/140VA

 

Switch terminal

Switch input terminals

10 pairs

 

The empty contacts

1-20mA, 24V 

Potential flip

"0": 0~+6V DC low level;

"1": +11~+250V DC high level

Switch output terminals

8 Pairs,

DC: 220V/0.2A;

AC: 220V/0.5A.

 

Time measurement range

Range

0.1ms~9999s

Accuracy

<0.1ms

 

Dimension & weight

Dimension

455×530×220mm

Weight

32Kg

 
Application:
Current Injection Relay Test Kit Six Phase Secondary Relay Protection Tester