• Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
  • Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
  • Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
  • Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
  • Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
  • Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester

Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Vlf Tester
Product Name: Vlf AC Hipot Tester
Power Supply: 220V 50Hz/60Hz
Measurement Accuracy: 2.5%
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz,0.01Hz
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
VLF
Output Voltage
30kv, 40kv,50kv, 60kv and 80kv
Application
Power Cable AC Withstand Voltage Test
Voltage Wave Form Distortion
<3%
Transport Package
Plywood Case for Vlf AC Hipot Tester
Specification
packing in 3 cases
Trademark
CHONGQING GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
100PCS/Month Hipot Tester

Product Description

Vlf Hi Pot Test High Voltage Tester Low Frequency VLF AC Hipot Tester

Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
 


How does vlf hipot tester work

The VLF hipot tester (Very Low Frequency High Potential tester) is a type of high voltage test equipment used to test the integrity and insulation quality of electrical power cables, transformers, motors, and other electrical equipment. Here is how it works:

The VLF hipot tester generates a very low frequency AC voltage, typically around 0.1 Hz, which is applied to the equipment under test. The voltage output of the tester can range from a few kilovolts to several hundred kilovolts, depending on the application.

The low frequency of the VLF AC voltage has two major advantages over traditional DC high potential testing. First, it minimizes the risk of damage to the insulation of the equipment under test, which can occur with DC testing due to the presence of capacitive charging currents. Second, it is more effective in detecting insulation defects, including weak spots, voids, and moisture, which can be missed by DC testing.

During the test, the VLF AC voltage is applied to the equipment under test for a period of time, typically several minutes, while the leakage current is measured. The leakage current is a measure of the insulation quality of the equipment, and any significant increase in the leakage current during the test indicates the presence of a defect in the insulation.

 

VLF hipot tester parameter

Model Output
Voltage/
Current
Load Capacity Fuse 
Tube
Frequency/
Capacitance
VLF-30KV 30KV/20mA 0.1Hz ≤ 1.1uF
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
5A
VLF-40KV 40KV/30mA 0.1Hz ≤ 1.1uF
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
6A
VLF-50KV 50KV/40mA 0.1Hz ≤ 1.1uF
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
7A
VLF-60KV 60KV/50mA 0.1Hz ≤ 1.1uF
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
10A
VLF-70 70KV/55mA 0.1 Hz, ≤ 0.5µ F
0.05Hz, ≤ 1.0µ F
0.02Hz, ≤ 2.5µ F
10A
VLF-80 80KV/60mA 0.1 Hz, ≤ 0.5µ F
0.05Hz, ≤ 1.0µ F
0.02Hz, ≤ 2.5µ F
12A


VLF hipot tester characteristic

Current, voltage and waveform data are all obtained directly by sampling from the high voltage side, so the data are real and accurate.

Over-voltage protection: When the output exceeds the set limit value, the instrument will shut down for protection, and the action time is less than 20 milliseconds.

Overcurrent protection: Designed as high and low voltage double protection, the high voltage side can be shut down precisely according to the set value.

The low voltage side will shut down when the current exceeds the rated current, and the action time is less than 20 milliseconds.

The high voltage output protection resistor is designed in the booster body, so there is no need to connect another protection resistor outside.

Due to the use of high and low voltage closed loop negative feedback control circuit, so the output is not capacitive rise effect.

 

Notes

  • Power supply requirement: AC50Hz, 220V, stability of frequency: fluctuation less than 0.5%.
  • When using it, the capacitance of the sample should not exceed the rated capacity of the instrument. The overlow capacitance of the sample will affect the output wave form. If the capacitance is less than 0.05µF, the instrument cannot output normally.
  • When using it, it is prohibited to boost voltage without load, or to connect with resistive load.

More details for Vlf hipot tester

Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester

Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester
Product Description

Vlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot TesterVlf Hi Pot Test High Voltage Tester Low Frequency Vlf AC Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now