Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1year
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
  • Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Find Similar Products

Basic Info.

Model NO.
GD-PQ200
Customized
Customized
Structure
Portable
Material
Aluminum
Certification
CE, ISO
Application
School, Lab
Type
Measurement Type
Product Name
Ferrous Debris Monitor
Feature
Oil Ferromagnetic Wear Particle Tester
Usage
Metal Abrasive Monitor
Power Supply
AC220V 50-60Hz
Ambient Temperature
0~30 Degree
Weight
4.2kg
Size
370mm*220mm*136mm
Measuring Range
0 ~ 15000pq
Test Time
7 S
Measurable Minimum
5pq
Resolution
1pq
Transport Package
Standard Wooden Case
Specification
ISO Certificate
Trademark
Gold
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
100PCS/Month

Product Description

PQ200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by
Manufacturer's Direct Sales
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Application Fields:
The iron meter developed by our company is a measuring device based on the principle of electromagnetic induction.. It can conveniently and quickly detect the content of ferromagnetic metal particles in lubricating oil, hydraulic oil, and lubricating grease, thereby judging the mechanical wear condition.
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Significance and Use:
1.This test method is intended for the application of PQ magnetometry in assessing the progression of wear in machinery, for example, engines and gearboxes, by trending the mass of ferrous debris in samples of lubricating oils or greases.
2.In-service oil analysis is carried out routinely by commercial laboratories on a wide range of samples from many sources and is accepted as a reliable means of monitoring machinery health by trend analysis. In particular, the extent of wear can be readily assessed from any changes in the ferrous debris burden within periodically extracted samples as reflected in the PQ Index.
3. PQ measurements can be used as a means of rapidly screening samples for the presence or absence of ferrous wear debris, allowing quick decisions to be made on whether or not to proceed to a more detailed spectroscopic analysis for probable wear metals in the sample.

 
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Performance Characteristics:
1. Adopting patented sensors and signal processing circuits, with good stability and high sensitivity.
2. The oil sample transmission and measurement are automatic, and one data can be measured in 10 seconds.
3. Equipped with PC data management software, measurement data can be directly imported into the computer for data management, trend analysis, curve printing, etc.
4. The oil sample does not need to be processed and can be directly injected into an oil bottle for measurement.
5. Chinese and graphical interface, convenient for user operation and use.
6. You can input any number and letter, and users can name the file.
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales

Technical Parameters:
1. Power supply: AC220V ± 10%, 50-60Hz;
2. Environmental temperature: 10 ºC~30 ºC;
3. Display screen: LCD120 ×90;
4. Repeatability: ± 4PQ or ± 1% [whichever is greater];
5. Resolution: 1PQ;
6. Test time: 7 seconds;
7. Measurable minimum value: 5PQ;
8. Detection range of abrasive particles: > 1 μ M ferromagnetic abrasive particles;
9. Serial port connection method: USB mother port;
10. Measurement range: 0~15000PQ;
11. Size: 370mm * 220mm * 136mm;
12. Weight: 4.2kg.

Packing Accessories:
No. Item name Quantity
1 PQ200 Ferrous Debris Monitor 1 pcs
2 USB connection cable 1 pcs
3 Power cable 1 pcs
4 2mL Oil bottle conversion ring 1 pcs
5 750PQ Standard sample 1 pcs
6  Oil Sample container 100 pcs
7 Manual 1 pcs
8 Warranty card 1 pcs
9 Glass fuse 3 pcs

Product Details Display:
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
After Service:
Service
Device Problem Handling Social media 24 hours online communication
Mail Seamless Docking
Video Conferencing
Pq200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer′s Direct Sales
Contact Us:
Welcome to contact us talk about details if you are interested in PQ200 Ferromagnetic Wear Analyzer Ferrous Wear Debris Monitoring by Manufacturer's Direct Sales
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier