Transformer Tan Delta Test Set Power Factor Tester

After-sales Service: Life Time Support Service
Warranty: 1 Year for Transformer Tan Delta Test Set Power Fa
Type: Transformer Tan Delta Test Set Power Factor Tester
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Related Products
Overview

Basic Info.

Model NO.
GDGS
Display
Digital
Control
Manual Control
Weight
30kg
Power Source
AC220V
Product Name
Transformer Tan Delta Test Set Power Factor Tester
Application Field
High Voltage Electrical Equipments in Power Plants
Operating Type
Fully Automatic
Capacitor Value
1%Rgd+5PF
Tangent Delta
1%Rdg+0.04%
Maximum Current
200mA
Testing Frequency
45Hz/55Hz
Environment Temperature
0-50°c
Transport Package
Wooden Case
Specification
550*490*580mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month Tan Delta Tester

Product Description

Transformer Tan Delta Test Set Power Factor Tester

Transformer Tan Delta Test Set Power Factor Tester


Introduction:

For on-site anti-interference dielectric loss measurement or precise dielectric loss measurement in the lab, a high-voltage dielectric loss test instrument is employed. High Voltage Transformer Tan Delta Tester has a built-in test transformer, variable frequency power supply, dielectric loss bridge, and standard capacitors. The measurement data is extremely reliable under heavy interference thanks to frequency conversion anti-interference and Fourier transform digital filtering technology. The measuring result is shown on a big LCD screen, and printing is possible using the micro-printer that is integrated.

Application:

Transformer Tan Delta Test Set Power Factor Tester
* In places with a lot of interference, such power plants or power substations, the GDGS Transformer Tan Delta Tester is used to test the dissipation factor (PF). For very accurate tests, it can also be utilized in laboratories.
* The GDGS Transformer Tan Delta Tester is a whole-in-one electronic circuit that includes a precise digital bridge, power unit, reference capacitor (CN), step-up transformer, and other circuits.
* Frequency shift technology, the FFT (Fast Fourier Transform method), and digital filtering are also used in the GDGS Transformer Tan Delta Tester. As soon as it is started, it runs automatically and outputs the findings on an LCD screen before printing them out automatically as well.



Technical Parameters:

1 Condition of Use -5°C~40°C, RH<80%
2 Power Source AC 220V±10% Without Frequency Limit


3


High Voltage Output
Range:0.5KV~10KV, every 0.1KV
Precision:5%
Maximum Current:200mA
Capacity:2000VA


4


Self-Excited Power
AC 0V~50V
Frequency:45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
Maximum Current:15A
5 Definition tgδ: 0.001% ; Cx: 0.001PF
6 Accuracy tgδ:±(reading*1.0%+0.040%)
Cx:±(reading*1.0%+1.00pF)



7



Measuring Range
tgδ: Without Limit
Cx:15pF
10KV:Cx<60nF
5KV:Cx<150nF
1KV:Cx<300nF
CVT Test:Cx<300nF
8 CVT range 10-10000
9 Weight 28kg


Testing of GDGS Transformer Tan Delta Tester:

Transformer Tan Delta Test Set Power Factor TesterTransformer Tan Delta Test Set Power Factor Tester

Related Products

Transformer Tan Delta Test Set Power Factor Tester

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters