Electronic Plastic Flammability Analyzer Needle Flame Tester IEC 60695
Introduction:
Electronic Plastic Flammability Analyzer Needle Flame Tester IEC 60695 is by national standards GB4706.1-1998 to design and produce.
Electronic Plastic Flammability Analyzer Needle Flame Tester IEC 60695 applies for lighting, low-voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical connectors, accessories, and other electrical and electronic equipment and parts, component research, production and quality control departments and insulating materials, plastic or other solid combustible materials industry to carry on small-flaming ignition experiments.
Electronic Plastic Flammability Analyzer Needle Flame Tester IEC 60695 ses standard size (Φ0.9mm) needle burner, burning the sample with specific gas (butane) at the angle of 45°.
Determine the ignition risk of the small flame caused by fault conditions in the equipment by testing the sample burning situation, burning time and burning length.
Standard:
IEC60695-2-2--- Fire Hazard Testing Part 2: Test Methods Section 2 - Needle-Flame Test
IEC60695-11-5--- Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
GB4706.1
GB5169.5-2008
Product Image:
Technical Parameters:
1, The needle burner is made of stainless steel.
2, The burner angle: 90°, 45°.
3, The combustion gases: 95% butane gas or propane gas.
4, Sub-plate: white pine plank ( 10mm),
--Surface covered by standard silk paper
--200mm±5mm below the flame
5, Temperature range: 0--1000 ºC.
6, The flame temperature requirements: 100 ± 2 ºC ~ 700 ºC ± 3 ºC.,
7, Heating rise time: 23.5 ± 1.0s.
8, Flame height: 12mm ± 1mm.
9, Ignition time: 0s ~ 999.9s adjustable, generally 30s.
10, Burning time: 0s ~ 999.9s, automatic recording, manual pause.
11, Test Space: ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements).
12, Temperature sensor: K-type insulation-sheathed thermocouple (Φ0.5mm)
13, Automatic test program, independent exhausting system;
14, Dimensions: 1120mm(L) * 520mm(W) * 1250mmmm(H),
---The diameter of exhaust :Φ100mm.
Specification:
Product Name |
Electronic Plastic Flammability Analyzer Needle Flame Tester IEC 60695 |
Power |
110V AC 60Hz / 230V AC 50Hz |
Ambient temperature |
10 ~ 35 ºC |
Relative humidity |
≤75% |
Air purity |
≥95% natural gas, propane |
Weight |
about 50kgs |