AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for AC Withstand High Voltage Resonance Tes
Type: AC Withstand High Voltage Resonance
Load Way: Electronic Load
Loading Method: Static Load
Display: Digital
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDXZ
Control
Digital Control
Weight
0-100Kg
Power Source
AC380V
Item
AC Withstand High Voltage Resonance Test System
Power Supply
380V±10% Three-Phase 50Hz
Rated Output Voltage
0-1000kv
Maximum Output Capacity
6400kVA
Working Frequency Range
30-300Hz
Quality Factor
30-80s
Frequency Adjustment Resolution
0.1Hz
Output Waveform
Sine Wave, Waveform Distortion Rate <1%
Transport Package
Wooden Case
Specification
620*430*330mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors

AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors


Product description

An AC resonant test system is a device used for testing the insulation performance of high voltage electrical equipment. It generates high voltage and high frequency signals through a resonant transformer and resonant circuit, and performs withstand voltage tests and partial discharge detection on the equipment to ensure safe and reliable operation under normal working conditions.

Product features
  1. Generates high voltage and high frequency electric and magnetic fields for withstand voltage tests and partial discharge detection
  2. Supports multiple test modes, such as amplitude mode, frequency mode, and phase mode
  3. Provides multiple protection functions, such as overcurrent protection, overvoltage protection, and overheat protection
  4. Can be operated through computer control for automated testing and data processing
  5. Displays test results and fault information for analysis and judgment by operators
 
AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors
AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors
AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors




Role of the main configuration

AC Withstand High Voltage Resonance Test System for Transformers/Cables/Motors


Variable frequency source: provides adjustable high-frequency voltage signals to generate the resonant effect in the resonant circuit. The variable frequency source can adjust the output frequency to match the characteristics of the tested equipment for accurate resonant testing.

Exciting transformer: boosts the output signal from the variable frequency source to the required high voltage level for testing. The exciting transformer is one of the key components in the resonant circuit, generating high voltage and high-frequency signals by transferring energy to the capacitors and inductors in the resonant circuit.

Reactor: limits the current in the resonant circuit to ensure stable operation. In the AC resonant test system, the reactor is usually used to limit the current in the resonant circuit to avoid overcurrent damage to the tested equipment or the exciting transformer.

Capacitive divider: measures the voltage in the resonant circuit to ensure testing accuracy and reliability. The capacitive divider divides the high voltage signal to a safe voltage level and transmits the divided signal to the testing instrument for measurement.

Indicator
 
power supply 380V±10%  three-phase 50HZ
rated output voltage 0-1000KV
maximum output capacity 6400KVA
working frequency range: 30-300HZ
quality factor 30-80s
frequency adjustment resolution 0.1HZ
output waveform sine wave, waveform distortion rate <1%
ambient temperature -15 ºC - 50 ºC humidity: ≤ 90% RH
Full power output, continuous working time of 60min
system with over-voltage, over-current, discharge and other fully automatic protection functions
Applicable scope: cable frequency resonance device, generator AC withstand voltage device, substation electrical equipment AC withstand voltage resonance device, CVT test with resonant boost device
Note: Frequency series resonance system configuration can be customized according to the test object and user use.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters