Transformer Dielectric Loss Dissipation Factor Tester Tan Delta Test Set

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Tan Delta Test Set
Product Name: Transformer Tan Delta and Power Factor Tester
Application Field: High Voltage Electrical Equipments in Power Plants
Operating Type: Fully Automatic
Capacitor Value: 1%Rgd+5PF
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGS
Tangent Delta
1%Rdg+0.04%
Maximum Current
200mA
Testing Frequency
45Hz/55Hz
Environment Temperature
0-50°c
Transport Package
Wooden Case
Specification
550*490*580mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month Tan Delta Tester

Product Description

Transformer Dielectric Loss Dissipation Factor Tester Tan Delta Test Set
 
Dielectric loss measurement is a very fundamental technique in the insulation test that is efficient in detecting both local faults and general moisture degradation of electrical equipment insulation. It is commonly utilized in electrical engineering, handover, preventative testing, and the installation of electrical equipment. The simplest way to gauge the effectiveness of insulation is to evaluate the dielectric loss of transformers, transformers, reactors, capacitors, bushings, arresters, etc.
The dielectric loss tester surpasses the conventional bridge measurement technique, adopts frequency conversion power supply technology, utilizes a single-chip microcomputer, and uses contemporary electronic technology to perform automatic frequency conversion, analog-to-digital conversion, and data calculation; achieves strong interference immunity, quick test speed, and high precision. Fully automatic digitalization and simple operation; power supply uses a high-power switching power supply; it outputs 45Hz and 55Hz pure sine waves, automatically regulates pressure, and can supply voltage up to 10kV; it also automatically filters out 50Hz interference, making it appropriate for situations with significant electromagnetic interference, like on-site substation testing. It is frequently used in the power sector to test the dielectric loss of transformers, transformers, bushings, capacitors, arresters, and other equipment.
Transformer Dielectric Loss Dissipation Factor Tester Tan Delta Test Set


Features:

* Transformer Dielectric Loss Dissipation Factor Tester uses Fourier transform digital filtering technology to measure characteristics such as capacitance and dielectric loss.
* In order to minimize 50Hz power frequency interference in the field, the instrument uses frequency converter technology. As a result, accurate data may be measured even in areas with significant electromagnetic interference.
* Employ full-touch very huge LCD, simple to use. Each step is obvious, there is a complete touch LCD screen, a huge full graphical operating interface, and no further technical knowledge is required for operators to operate. With a touch, the entire process may be measured.

Transformer Dielectric Loss Dissipation Factor Tester Tan Delta Test Set

Specifications:

Accuracy: Cx ±(reading×1%+1pF)

               PF ±(reading×1%+0.00040)

Interference Ratio: Interference current is no more than 2 times of the test current

Capacitance Range: Internal HV  3pF~60000pF / 10kV,60pF~1uF/0.5kV External HV     3pF~0.3uF/10kV

                              Resolution   0.0001pF, 4 digital

PF Range: No limit, Resolution 0.001%, C/L/R specimen test

Input current range: 10μA~1A

Internal HV: 0.5~10kV / 200mA (max)

HV Adjust: Rise or fall smoothly

HV Accuracy: ±(reading×1%+10V) Resolving 1V

Frequency select: 60Hz single point, locked 55Hz/65Hz double point, locked

Test Time: 40S typical

Power Supply: 180V~270V 50Hz/60Hz auto

Operating Temperature: 0ºC~60ºC

storage Temperature: -20ºC~60ºC

Humidity: <90%

Transformer Dielectric Loss Dissipation Factor Tester Show:

Transformer Dielectric Loss Dissipation Factor Tester Tan Delta Test SetTransformer Dielectric Loss Dissipation Factor Tester Tan Delta Test SetTransformer Dielectric Loss Dissipation Factor Tester Tan Delta Test Set

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters