Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Transformer Tan Delta Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester
  • Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester
  • Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester
  • Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester
  • Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester
Find Similar Products

Basic Info.

Model NO.
GDGS
Power
Electronic
Output Voltage
AC 0.5kv~10kv
Testing Voltage Setting Resolution
0.5kv
Maximum Output Capacity
200mA
Testing Frequency
45Hz/55Hz
Test Mode
Fully Automatic
Tangent Delta
1%Rdg+0.04%
Transport Package
Plywood Case
Specification
470mm(L) × 320mm(W)× 390mm(H)
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
100 Set/Sets Per Month

Product Description

GDGS Touch Screen Transformer IPF Insulation Power Factor Tester Tan Delta Tester

Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester

Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester

HV Output Terminal by GDGS IPF Tester



Introduction:
GDGS Touch Screen Transformer IPF Insulation Power Factor Tester Tan Delta Tester

  • GDGS Automatic Transformer Power Factor Tester, Transformer Tan Delta Tester is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

  • It can also supply high voltage source for testing.

  • Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

  • It can also use generator as power supply;

  • If equipped with a insulation oil vessel and a temperature detector, it can also measure tan delta of insulation oil;


Specifications:
GDGS Touch Screen Transformer IPF Insulation Power Factor Tester Tan Delta Tester

 
No. Item GDGS Touch Screen Transformer IPF Insulation Power Factor Tester Tan Delta Tester
1 Accuracy Cx±(reading×1%+1pF)
PF±(reading×1%+0.00040)
2 Interference Ratio Interference current is no more than 2 times of test current
3 Capacitance Range Internal HV:  3pF~60000pF / 10kV,60pF~1uF/0.5kV
External HV  3pF~0.3uF/10kV
Resolution  0.0001pF, 4 digital
4 PF Range No limit, Resolution 0.001%, C/L/R specimen test
5 Input current range 10μA~1A
6 Internal HV 0.5~10kV / 200mA (max)
7 HV Adjust Rise or fall smoothly
8 HV Accuracy ±(reading×1%+10V) Resolving 1V
9 Frequency select 60Hz single point, locked 55Hz/65Hz double point, locked
10 Test Time 40S typical
11 Power Supply 180V~270V 50Hz/60Hz auto
12 Operating Temperature 0ºC~60ºC
13 Storage Temperature -20ºC~60ºC
14 Humidity <90%


Working Principle:
GDGS Touch Screen Transformer IPF Insulation Power Factor Tester Tan Delta Tester

 
  • In the AC voltage, the dielectric to consume part of the energy, this part of the energy will be converted to heat energy loss. This energy loss is called dielectric loss.
  • When AC voltage is applied on the dielectric, the dielectric between voltage and current in phase difference angle psi, delta psi is called the dielectric loss angle tangent TG delta delta is called dielectric loss tangent. TG delta value is used to measure dielectric loss parameters. The instrument measuring circuit includes a standard circuit (Cn) and a test loop (Cx), as shown in Figure 2 - 1. The standard circuit is composed of a built-in high stability standard capacitor and a measuring circuit. Measurement line sampling resistor with pre amplifier and A/D converter. By measuring circuit are respectively measured by standard test and loop current loop current amplitude and phase difference, then the digital signal processor using digital real-time acquisition method, obtained through vector operation test of capacitance and dielectric loss tangent value. The anti-interference measures have been adopted in the instrument to ensure the accurate measurement under the interference of external electric field.
Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester



Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta TesterGdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester

Order & Customer Feedback:
Transformer IPF Power Factor Tester Tan Delta Tester

Gdgs Touch Screen Transformer Ipf Insulation Power Factor Tester Tan Delta Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier