• Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
  • Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
  • Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
  • Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
  • Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
  • Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1

Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1

After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year for Tansformer TTR Tester
Application: Turns Ratio and Group Vector Test of Transformer
Test Standard: IEC76-1, IEC60044
Ratio Measurement Range: 1-10000
Group Measurement: 1-12
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDBC-901 TTR Tester
Ratio Measurement Error
1-10000 ± 0.2%Rdg
Test Voltage
0~80V, Frequency 50Hz
Power Supply
AC220V ± 10%, 50Hz/60Hz
Phase Measurement Error
1 Degree
Transport Package
Plywood Case
Specification
22KG
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

GDBC-901  Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
Introduction

GDBC-901  Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1 is designed according IEC76-1 and IEC60044. 
GDBC-901 IEC Single and Three Phase Transformer Turns Ratio Testing Transformer Ratio TTR Meter could be applied to test the turns ratio and group vector of single or three phase transformer. 
Also the connection group of transformer could be calculated with the ratio. 
All parameters are measured in one test for three phase transformer.



Function
  • The voltage ratio measurement for three or singe phase transformer 

  • The group vector measurement for three phase transformer.

  • The polarity measurement for single phase transformer or CT/PT

  • Voltage ratio error calculation

  • Current transformer ratio measurement

  • Excitation current measurement in ratio testing

  • Reproduction the AC test voltage from power source to reduce the effects of bad power source

  • Save the test results in the memory internal the tester

  • Print the test results by micro printer

  • Reverse connection detect unit to prevent the high voltage injected to operator

  • Over current protection unit integrated in software and hardware

  • Upload the test results to PC by RS232 and make word report by software

 

Technical Index

1 Item Name GDBC-901  Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
2 Ratio measurement range 1-10000
3 Group measurement 1-12
4 Phase measurement error 1 degree
5 Ratio measurement error 1-2000 ± 0.2%RDG   2000-10000  ± 0.5%RDG
6 Test voltage 0~80V, frequency 50Hz
7 Power supply AC220V ± 10%, 50Hz/60Hz
8 Environment temperature 0-50°C
9 Humidity ≤85%R
10 Dimension 58*45*36CM
11 Weight 22Kg


Product Details

Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1

Test Results

Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1

Certificate of Calibration

Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1


Customer Visit
Gdbc-901 Automatic Transformer Turns Ratio Meter Single Phase Transformer TTR Tester IEC76-1
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now