BS 476-7 Flammability Analyzer Flame Spread Tester For Building Materials
Introduction:
BS 476-7 Flammability Analyzer Flame Spread Tester For Building Materials is measuring the lateral spread of flame along the surface of the specimen of a product orientated in the vertical position under opposed flow conditions, and a classification system based on the rate and extent of the spread of flame. It provides data suitable for comparing the end-use performances of essentially flat materials, composites or assemblies, which are used primarily as the exposed surfaces of walls and ceilings.
Application:
Building Materials
Rail
Standard:
>>> BS 476-7---Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products.
Specifiastion:
1, This BS 476-7 Flammability Analyzer Flame Spread Tester For Building Materials mounted vertically in a surround and supported on a framework.
2, The radiation panel is sullied with an gas-air mixture.
3, The radiation panel is 850mm square for a porous refractory type burner block designed to give efficient combustion of the air-gas-air mixture, with no flaming occurring on the face of the panel under operational conditions.
4, The radiation panel and its surround are supported on a framework so that the center of the panel is about 1250±100mm above floor level.
5, A specimen holder and a pilot flame arrangement mounted to one side of the apparatus.
6, The specimen holder is comprise a water-cooled steel frame with water-cooled face plates. The face plates is overlap the specimens by 20±2mm on their top and bottom edges and over the vertical edge adjacent to the radiation panel.
7, A spring loaded clamp is positioned to clamp the specimen against the face plates.
8, The portable water supply to the specimen holder make the maximum temperature does not exceed 35ºC at the outlet from the specimen holder.
9, The specimen holder assembly is located at 90±2° to the face of the radiation panel and in such as way that the faces of the top and bottom guides of the specimen holder are in the same plane as the inside face of the surround to the radiation panel.
10, The height of the specimen holder is hinged to allow it to be swung horizontally, away from the face of the radiation panel between tests, from the test position to the standby position and vice-versa.
Installation Requirement:
Product Name | BS 476-7 Flammability Analyzer Flame Spread Tester For Building Materials |
Electrical | 230 volts Nominal 10 Amps |
Ambient Temperature | Operating 10°C to 35°C |
Gas Supplies | Propane and air compressor |
Testing Room | 400m3 |
Size | 1220 mm (W) x 550 mm (D) x 1920 mm (H) |
Weight | About 200 kg |