Current Transformer Potential Transformer Test Instrument CT PT Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Current and Potential Transformer Test
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
  • Current Transformer Potential Transformer Test Instrument CT PT Tester
Find Similar Products

Basic Info.

Model NO.
GDVA-405
Product Name
Current Transformer Potential Transformer Tester
Test Standards
IEC60044-1/2/5/6
Accuracy
0.02%(Typical), 0.1% (Guaranteed)
Voltage Output
0.1~180V (AC)
Power Output
500va
Current Output
0.001-5A(RMS)
Maximum Knee Voltage
45kv
Current Measurement Range
0~10A
Power Supply
220V 50Hz
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Current Transformer Potential Transformer Test Instrument CT PT Tester

Current Transformer Potential Transformer Test Instrument CT PT Tester

The CT PT tester is an electronic instrument used to calibrate and verify these transformers, providing accurate and automated testing capabilities for current and voltage transformers. The CTPT transformer is a key component that steps down high currents and voltages to safer levels for measurement, protection and control purposes. It has a DSP data acquisition system that can complete data acquisition for variable frequency power supply control and test processes.

* Higher accuracy and test stability.
* The tester has a wider range of functions.
* Larger storage capacity, more than 5000 groups.
* Simple operation, data analysis, storage and interface display are all completed by the industrial computer system.


Main Test items

Tests for CT Tests for CP
1. Excitation curve and parameters test 1. Turns ratio test
2. Turns ratio test 2. Ratio error and phase angle error test
3. Ratio and phase error test 3. Polarity test
4. Polarity mark check 4. Secondary burden test
5. Winding resistance measurement 5. Winding resistance test
6. Secondary loop burden measurement  
7. Error line curve test for protection CT  
8. Transient CT parameters test  
9. CT nameplate guess  
10. Saturation hysteresis loop curve measurement  

Applications

1. CT nameplate check
2. CT parameters check in work burden
3. CT transient parameters analysis
4. CT ratio and phase error calibration
5. PT routine test


Specifications

1 Test Standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC61869,C57.13
2 Power supply AC220V±10%, 50/60Hz±10%(Support customize)
3 Voltage output 0.1-180V (AC)
4 Current output 0.001-5A(RMS)
5 Power output 500VA
6 Max.  knee voltage measurement 60KV
7 Current measurement Range: 0-10A (automatically change  range in 0.1/0.4/2/10A),

Error: <±0.1%+0.01%FS

8 Voltage measurement  Range:0-200V (automatically change range in 1V/10V/70V/200V).

Error: < ±0.1%+0.01%FS

9 Turns ratio measurement Range 1-35000
1-2000, error<0.05%
2000-5000,error<0.1%
5000-35000,error<0.2%
10 Phase measurement Error:±2min

Resolution: 0.01min

11 Winding resistance measurement 

Range: 0-8kΩ (automatically change range in 2 ohm/20 ohm/80 ohm/800 ohm/8 kohm).

Error: < 0.2%RDG+0.02%FS.

Max resolution :  0.1mΩ.

12 CT Secondary burden  Range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm).

Error:  <0.2%RDG+0.02%FS.

Max resolution : 0.001ohm.

13 PT Secondary burden Range:0-80kohm (automatically change range in 800ohm/8kohm/80kohm).

Error: <0.2%RDG+0.02%FS

Max resolution : 0.1ohm.

14 PT ratio measurement range

1-35000,

1-10000, error<0.1%,

10000-35000, error<0.2%

15 PT ratio error measurement Typical error<0.05%,  Max Error<0.1%
16 PT phase angle measurement max error: < 3min

User Interface

Current Transformer Potential Transformer Test Instrument CT PT Tester

 Standard configuration
 

Name  QTY  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  
Current Transformer Potential Transformer Test Instrument CT PT Tester


Customer Feedback

Current Transformer Potential Transformer Test Instrument CT PT Tester
Current Transformer Potential Transformer Test Instrument CT PT Tester
 
Details show
Current Transformer Potential Transformer Test Instrument CT PT Tester
 

Current Transformer Potential Transformer Test Instrument CT PT Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier