• Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control
  • Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control
  • Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control

Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year
Appliance: Transformer Oil Analysis
Detector: FID
Mobile Phase: Liquid
Chromatography Type: Liquid Chromatography
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
GD-3100
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
10mm
Product Name
High Performance Liquid Chromatography
Application
Furfural Furan Analysis in Transformer Oil
Flow Rate Range
0.001-10.000 Ml/Min, in 0.001 Ml Increments
Flow Accuracy
≤±0.2% (1.00ml/Min, H2O, R.T., 8.5MPa)
Flow Precision
Rsd≤0.06% (1.00ml/Min, H2O, R.T., 8.5MPa)
Maximum Pressure
45 MPa
UV3100 UV/Vis Detector
Wavelength Range: 190-700 Nm
O3100 Colunm Oven
3 Columns
Chromatographic Data-Process Workstation
Internal and External Standard Calculation Methods
UV3100 UV/Vis Detector 2
Bandwidth: 8nm
Transport Package
Plywood Case
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

GD-3100 Variable Wavelength Detector Transformer Oil Gradient HPLC System With PID Control
Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control
GD-3100 Variable Wavelength Detector Transformer Oil Gradient HPLC System With PID Control is updated from P230H HPLC System. It's the higher and more reliable quality product with samples analysis.

 

System Configuration

  • Isocratic system
  • High-pressure binary gradient system
  • Quaternary low-pressure gradient system
  • ELITE-AAK/AAP amino acid analytical system

 

Characteristics

1) Classic short stroke,serial pitsons,and multi-stage flow correction ensuring pump performance.

2) Concave surface holographic grating and intelligent power supply for lamp steadily improving detector functioning.

3) Self-development PID control measure bringing true the accuracy of column oven temperature to 0.1ºC.

4) The brand-new S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.

5) Application of optoelectronic isolation and EMI protection ensuring stable communication.

6) All-round upgraded Chromsoft workstation that is operator-friendly and promotes customer experience.

 

Configuration Table

1

P3100 High Pressure Constant Flow Pump

1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments

2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)

3) Flow precision: RSD≤0.06%  (1.00ml/min, H2O,R.T.,8.5MPa)

4) Maximum pressure: 45 MPa

5) Pressure accuracy: ≤±3.0%

6) Pressure pulsation: ≤0.1 MPa

2

UV3100 UV/VIS Detector

  • Wavelength range: 190-700 nm
  • Wavelength repeatability: ≤0.1 nm
  • Wavelength accuracy: ≤±1.0 nm
  • Bandwidth: 8nm
  • Response time: 0.0 s-5 s
  • Baseline noise: ≤±0.5×10-5 AU
  • Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm(analytical cell)
  • Light source:  Lamp
3

Chromsoft Chromatographic Data-processing Workstation

  • Internal and external standard calculation methods
  • Automatically displays, prints, exports and starts other programs after the completion of a measurement.
  • Comply with the requirements of the 21 CFR Part 11 directive of the FDA.
4

GD-3100 System Kits

  • Containing required tubing, fittings, wreches and cables for system.
  • 7725i manual injector
  • TD-1-15 static mixer
  • Supersil ODS2 5μm ID4.6*200mm
5

S3100 Autosampler

(optional)

  • Inject volum range: 0-100 μL (standard)
  • Precision: RSD <0.3%
  • linearity: >0.999
  • Sample residual: <0.01%
  • Number of sample plates: Two of 60 position 2-mL vial plates
  • Syringe: 500 μL
6

O3100 Colunm Oven

  • Column capacity: Three columns, up to 10mm internal diameter, up to 250mm length with guard column
  • Temperature range: Ambient+5.0 to 80ºC, settable in 0.1ºC increments
  • Temperature accuracy: ≤±0.5ºC
  • Temperature stability: ≤±0.1ºC
7

Pretreatment

(optional)

  • Ultrasonic Bench Top Cleaner
  • Φ13mm/Φ25mm Nylon (organic) (100/pk)
  • Φ13mm/Φ25mm Cellulose (aqueous) (100/pk)
  • Diaphragm Vacuum Pump
  • Φ50mm Solvent Filter (Include Nylon and Cellulose, 100/pk)

Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control
Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control

Success Case

 
A Transformer Oil Lab from Philippines Ordered 8 Sets Equipment

Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control

A Transformer Oil Lab in Manila,Philippines who placed an order with us on July 11,2019. Total 8 equipment. which includes:

  • GDYJ-502A 80KV Transformer Oil BDV Tester,
  • GDGY Transformer Oil Tan Delta Tester,
  • GC-7890-DL Transformer Oil Dissolved Gas Analyzer
  • GD-2100 Karl Fischer Moisture Titrator(Coulometric method)
  • GD-6541A Automatic Interfacial Tension Tester
  • GD-752N UV Vis Spectrophotometer
  • GD-3100 Gradient HPLC System
  • GD-105 Automatic Acid Number Tester (ASTM D974)
    We will provide a training in their lab.
Company Profile

Variable Wavelength Detector Transformer Oil Gradient HPLC System with Pid ControlVariable Wavelength Detector Transformer Oil Gradient HPLC System with Pid ControlVariable Wavelength Detector Transformer Oil Gradient HPLC System with Pid Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters