• Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
  • Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
  • Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
  • Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
  • Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
  • Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets

Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for 0.01Hz Vlf Dielectric Test Sets
Type: 0.01Hz Vlf Dielectric Test Sets
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 3200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
VLF
Display
Digital
Control
Manual Control
Weight
as Different Size
Power Source
AC220V
Product Name
0.01Hz Vlf Dielectric Test Sets
Test Standard
IEC60060
Rated Voltage
30kv,40kv,50kv,60kv,80kv
Rated Current
20mA,30mA
Load Carrying Capacity
0.1Hz;0.05Hz;0.02Hz
Power Fuse Wire
5A,7A,9A,12A
Measurement Accuracy
2.5%
Voltage Wave Form Distortion
<3%
Power Supply
AC220V ± 10%, 50Hz/60Hz
Leakage Current Measurement Error
<2.5%
Transport Package
Plywood Case
Specification
as different size
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
200piece/Month

Product Description


Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets

Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets


Introduction:

  • VLF Tester is designed and manufactured for electrical equipment very low frequency withstand voltage test.

  • Very low frequency withstand voltage test is essentially an alternative of power frequency withstand voltage test. It is much smaller, lighter and portable than power frequency withstand voltage tester. It is proved home and abroad that 0.1Hz ultra-low frequency withstand voltage test can replace power frequency withstand voltage test.

  • It can be applied for 10kV, 35kV, 300MW thermal power machine, 10kV, 35kV power transformer and other electrical equipment

 

Specifications:
 

  • Max voltage output: refer to following table;

  • Output frequency: 0.1Hz, 0.05Hz, 0.02Hz;

  • Measurement accuracy: 2.5%;

  • Positive and negative voltage peak errors < 2.5%RDG+0.3%FS;

  • Voltage wave form distortion:<3%;

  • Insulation resistance measurement error:<2.5%;

  • Leakage current measurement error:<2.5%;

  • Power supply:AC220V ± 10%, 50Hz/60Hz;

  • Environment temperature: 0~50°C;

  • Humidity:≤85%RH;

Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets

 

Model Rated Voltage/current Load Carrying
Capacity
Power fuse wire Product Structure and Weight
30 30kV/20mA
(Peak)
0.1Hz,≤0.5µF~1.1µF 5A Controller:4kg
Booster: 25kg
0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
50 50kV/30mA
(Peak)
0.1Hz,≤0.5µF~1.1µF 7A Controller:4kg
Booster: 50kg
0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
60 60kV/30mA
(Peak)
0.1Hz,≤0.5µF 9A Controller:4kg
Booster Grade 1(30kV):25kg
Booster Grade 2(30kV):25kg
0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF
80 80kV/30mA
(Peak)
0.1Hz,≤0.5µF 12A Controller:4kg
Booster Grade 1(30kV):25kg
Booster Grade 2(50kV):50kg
0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF

 

Features:

  • Data of current, voltage and wave form can be directly sampled at high voltage side, so the data is real and accurate;

  • Over-voltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself; the actuation time is less than 15ms;

  • Over-current protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 15ms;

  • A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside;

  • As a result of high and low voltage closed-loop negative feedback control circuit, the output without capacitive rise effect;

  • High-voltage control part adopts innovative light control HV switching unit, control is accurate, safe and reliable;

  • With color man-machine interface touch control plus controls modular software operating system, precise and intuitive;

  • Multi-purpose, can simultaneously measure tested objects capacitance, insulation resistance, leakage current, and AC withstand voltage test;
     

Real Pictures:

Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets
Very Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test SetsVery Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test SetsVery Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test SetsVery Low Frequency Hipot Tester 0.01Hz Vlf Dielectric Test Sets

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters