• UL94 Horizontal Vertical Flame Test Chamber
  • UL94 Horizontal Vertical Flame Test Chamber
  • UL94 Horizontal Vertical Flame Test Chamber
  • UL94 Horizontal Vertical Flame Test Chamber
  • UL94 Horizontal Vertical Flame Test Chamber
  • UL94 Horizontal Vertical Flame Test Chamber

UL94 Horizontal Vertical Flame Test Chamber

Product Name: UL94 Horizontal Vertical Flame Test Chamber
Standard: UL 94
Size: 1, 510(W) * 630(D) * 1, 400(H)mm
Power: 220 V AC, 60 Hz, 1 a
Weight: 60 Kg
Manual: Supplied
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-UL94
Utilities
Remote Controller, Methane Gas, 2 Stage Regulator
Vent & Exhaust Fan
Open/Close, 1.4 M3/Min
Warranty
12 Months
Transport Package
Plywood Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

UL94 Horizontal Vertical Flame Test Chamber  

Introduction:   

UL 94 measures the combustion properties (after flame, afterglow) by burner (H-5025 UL Tirrell burner) when test sample combusts in chamber's internal volume of 0.864m3 and is installed internal light to observe the specimen's properties and has a ventilating opening with emission fan to remove the combustion gas.

UL 94-AVH has auto specimen moving system for protecting the user from hazardous gas and auto burner moving system for meeting the whole test standards. This auto burner moving system has a goniometer, so it can change the angle of flame to the specimen (0˚, 20˚, 30˚, 45˚, 90˚).

Control box and remote controller help the user to handle this equipment or check after flame time and afterglow time during testing and are able to adjust the angle. 
 

Standard:   

1.Horizontal Burning Test: UL 94HB (ASTM D 5048 or ISO 10351).

2.Vertical Burning Test : UL 94 V-0, V-1, or V-2 (ASTM D 3801, IEC 707, or ISO 1210).

3.500w (125mm) Vertical Burning Test: 5VA or 5VB (ASTM D  4804 or ISO 9773).

4.Thin Material Vertical Burning Test: VTM-0, VTM-1, or VTM-2 (ASTM D 4804 or ISO 9773)

5.Horizontal Burning Foamed Material Test: HBF, HF-1, or HF-2 (ASTM D 4986 or ISO/DIS 9772.3)

6.KS M 3015: A testing method for thermosetting plastics

7.KS M 3305: Liquid unsaturated polyester resins for fibre-reinforced   plastics

8.KS M 3809: Thermal insulation material made of rigid urethane foam

9.KS M ISO 9772: Cellular plastics-Determination of horizontal burning characteristics of small specimens subjected to a small flame

 

Feature:   

  1. Auto specimen moving system (The Switch 'MOVE1' in the control box enables random control and operation by user) facilitating automatic movement and removal of sample to the ignition source.

  2. Auto Burner Moving System (The Switch and Remote Controller switch 'MOVE2' in the control box enables random control and operation by user) enabling adjustment of different ignition time and burner angles by standards.

  3. Auto Burner Lifting system (The Switch and Remote Controller switch 'MOVE3' in the control box enable random control and operation by user) enabling the adjustment of different height of the specimen and apply to lift flame to specimen.

  4. Cable Handy Remote Controller facilitating the operation of Timer 1,2 and 3 in the UL 94-AVH Control Box and Auto Burner Moving System.

  5. Double-coated chamber equipped with an exhaust fan to readily discharge combustion gas and internal lighting, whose internal volume is 0.864 m3.

  6. Burner Calibration Kit to measure 20mm flame and 125mm flame under ASTM D 5207 (Copper slug thermocouple and digital thermal indicator for 20mm flame and 125mm flame).

  7. Thermal Indicator and Thermocouple Connector in the control box facilitating calibration of flame calories by the Copper Slug(ASTM D 5207).

  8. Burner complying with ASTM D 5025 equipped with the precision control system including goniometer facilitating adjustment of burner angles(0˚, 20˚, 30˚, 45˚, 90˚), frame, and gas flow meter in addition to a manometer.

  9. Control Box adjustable at intervals of 30 degrees facilitating time adjustment and operation of the timer by user's location.

  10. Sliding Door made of reinforced glass to observe sample and prevent a user from inhaling noxious gases during the test.

  11. 2 access ports on the front of the chamber to protect the user from inhaling noxious gases, adjust the burner and devices in the chamber, and move and fix samples.

  12. Clamp facilitating separation and attachment of the test sample.

  13. Units and accessories to change flame shape and burner angle in diverse test methods by standards(For example, accessories capable of HBF, HF, and ISO 9772 tests).

  14. 3 digital timers to measure simultaneously the time of after flame, afterglow and after flame.

Test result: 

  1. After flame: Flame continued even after a firing source disappears   

  2. After flame Time: Time is taken for after flame continued under specified conditions(unit: second)

  3. Afterglow: Glowing combustion continued even after an ignition source and flame disappear   

  4. Afterglow Time: Time is taken for afterglow continued under specified conditions (unit: second)   

  5. Damaged length (Damaged length of test sample, unit: mm)

  6. Ignited the cotton indicator by drip flaming(Ignition of cotton by a dropped flame piece) 

Product Image:
UL94 Horizontal Vertical Flame Test Chamber
UL94 Horizontal Vertical Flame Test Chamber
UL94 Horizontal Vertical Flame Test Chamber
UL94 Horizontal Vertical Flame Test Chamber
 

Specification:   

Product name UL 94 Plastic Flammability Tester
Standard UL 94 
Size 1,510(w) × 630(D) × 1,400(H)mm
Power 220 V AC, 60 Hz, 1 A
Weight 60 kg
Manual Supplied
Utilities Remote controller, Methane Gas, 2 stage regulator, Ventilation Hose
Vent & Exhaust fan Open/Close, 1.4 m3/min

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area