• Transformer Turn Ratio Tester TTR Meter with PC Connection
  • Transformer Turn Ratio Tester TTR Meter with PC Connection
  • Transformer Turn Ratio Tester TTR Meter with PC Connection
  • Transformer Turn Ratio Tester TTR Meter with PC Connection
  • Transformer Turn Ratio Tester TTR Meter with PC Connection
  • Transformer Turn Ratio Tester TTR Meter with PC Connection

Transformer Turn Ratio Tester TTR Meter with PC Connection

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Turn Ratio Tester TTR
Type: Transformer Turns Ratio Tester TTR Meter
Accuracy Grade: 0.2%
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDBC-901
Display
Digital
Control
Fully Automatic
Weight
22kg
Power Source
AC220V
Short Name
Transformer TTR Tester
Test Standards
IEC76-1, IEC60044
Ratio Measurement Range
1-10000
Application
Turns Ratio and Group Vector of Transformer and CT
Ratio Measurement Error
1-10000± 0.2%Rdg
Test Voltage
0~80V, Frequency 50Hz
Phase Measurement Error
1 Degree
Group Measurement
1-12
Transport Package
Plywood Case
Specification
400*350*200mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

GDBC-901 Transformer Turns Ratio Tester TTR Meter with PC Connection

Transformer Turn Ratio Tester TTR Meter with PC Connection

How to perform a power transformer turns ratio test

 

Power transformer turns ratio test is an   an AC low voltage test  which determines the ratio of the high    voltage winding to all other windings at no-load. The turns ratio test is performed on all taps of every winding.

The Transformer Turns Ratio tester (TTR) is a device utilized to determine the ratio of turns between the windings in a transformer. It applies voltage to the leads marked with "H" and measures the resulting voltage on the lead marked with "X" using the testing equipment.

The ratio measurements are performed on all tap positions, and the ratio is calculated by dividing the measured induced voltage by the applied voltage. In the case of three-phase transformers, the ratio is measured individually on each phase using a three-phase TTR, and the process is repeated until ratio measurements for all three phases are completed.
Transformer Turn Ratio Tester TTR Meter with PC Connection


Transformer Turn Ratio Tester TTR Meter with PC Connection

Introduction

  • The voltage ratio measurement for three or singe phase transformer 

  • The group vector measurement for three phase transformer.

  • The polarity measurement for single phase transformer or CT/PT

  • Voltage ratio error calculation

  • Current transformer ratio measurement

  • Excitation current measurement in ratio testing

  • Reproduction the AC test voltage from power source to reduce the effects of bad power source

  • Save the test results in the memory internal the tester

  • Print the test results by micro printer

  • Reverse connection detect unit to prevent the high voltage injected to operator

  • Over current protection unit integrated in software and hardware

  • Upload the test results to PC by RS232 and make word report by software

 

Specifications

1 Item Name GDBC-901 Transformer Turns Ratio Tester TTR Tester with PC Connection
2 Ratio measurement range 1-10000
3 Test Standards IEC76-1,IEC60044
4 Group measurement 1-12
5 Phase measurement error 1 degree
6 Ratio measurement error 1-2000 ± 0.2%RDG   2000-10000  ± 0.5%RDG
7 Test voltage 0~80V, frequency 50Hz
8 Power supply AC220V ± 10%, 50Hz/60Hz
9 Environment temperature 0-50°C
10 Humidity ≤85%R
11 Dimension 58*45*36CM
12 Weight 22Kg
 
 
Test Results

Transformer Turn Ratio Tester TTR Meter with PC Connection
Packing

Transformer Turn Ratio Tester TTR Meter with PC Connection
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters