After-sales Service: | Lifetime Technical Support,Online Service |
---|---|
Warranty: | 1 Year |
Power Supply: | AC220V±10%, 50/60Hz±10% |
Working Condition: | Temperature: -10ºC~50ºC; Moist: ≤90% |
Memory Capacity: | >1000 Groups Test Results |
Standards: | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C |
Customization: |
---|
Suppliers with verified business licenses
Transformer Tester Appliction
Tests for Current Transformer:
Tests for Voltage Transformer:
Applications of CT/PT Analyzer:
CT PT Analyzer Technical Index
1 | Test standards: | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC61869,C57.13 |
2 | Power supply: | AC220V±10%, 50/60Hz±10% |
3 | Voltage output: | 0.1~180V (AC) |
4 | Current output: | 0.001~5A(RMS) |
5 | Power output: | 500VA |
6 | Maximum knee voltage measurement: | 45KV |
7 | Current measurement: | Range:0~10A (automatically change range in 0.1/0.4/2/10A) ; Error: <±0.1%+0.01%FS |
8 | Voltage measurement:Range: | 0~200V (automatically change range in 1V/10V/70V/200V) ; Error: < ±0.1%+0.01%FS |
9 | Turns ratio measurement:Range:1~35000 | 1~2000 error<0.05% |
2000~5000 error<0.1% | ||
5000~35000 error<0.2% | ||
10 | Phase measurement: | error: ±2min; resolution: 0.01min |
11 | Winding resistance measurement: |
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) |
Error: < 0.2%RDG+0.02%FS | ||
Maximum resolution:0.1mΩ | ||
12 | Temperature measurement: | -50~100 Celsius degree; error<3 Celsius degree |
13 | CT Secondary burden: Range: |
0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) |
Error: <0.2%RDG+0.02%FS | ||
Maximum resolution:0.001ohm | ||
14 | PT Secondary burden: | PT ratio measurement:Range: 1~35000 |
Range: | 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) | |
Error : | <0.2%RDG+0.02%FS | |
Maximum resolution: | 0.1ohm | |
15 | 1~10000 error | <0.1% |
10000~35000 erro | <0.2% | |
16 | PT ratio error measurement: | Typical error <0.05%, Maximum Error<0.1% |
17 | PT phase angle measurement: | maximum error < 3min |
18 | Make evaluation for test results according to selected standards | |
19 | Make word report for test result | |
20 | Make word reports one time for multi-group test records on the PC | |
21 | Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test | |
22 | Compare excitation curves with saved excitation curves in the same window | |
23 | Memory capacity: >1000 groups test results | |
24 | Working condition: temperature: -10ºC~50ºC; moist: ≤90% | |
25 | Size: 485mm×356mm×183mm | |
26 | Weight: <15kg |
Package:
Suppliers with verified business licenses