Warranty: 1 Year for Transformer Dielectric Loss and Tan Del
Product Name: Transformer Dielectric Loss and Tan Delta Tester
Test Standard: IEC60076
Max Output Voltage: 10kv (12kv for Choice)
Maximum Current: 200mA
Samples:
US$ 3500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Specifications
  • Product Pictures
Overview

Basic Info.

Model NO.
GDGS
Capacity
2000va
Measuring Range
Cx: 15PF<Cx<300NF
CVT Test
Cx <300 NF
CVT Range
10~10000
Transport Package
Plywood Case
Specification
ask the salesman
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

12kv Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester 
 
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester
 
  • GDGS Automatic Transformer Power Factor Tester, Transformer Tan Delta Tester is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

  • It can also supply high voltage source for testing.

  • Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

Specifications

 

No.

Item Name

GDGS Automatic Transformer Power Factor Tester

1

Use conditions

-15ºC∽40ºC

RH<80%

2

Anti-interference

Frequency conversion

3

Power

AC 220V±10%

 

4

High output

0.5KV∽10KV

Every 0.1kV

Precision

2%

Maximum current  

200mA

Capacity

2000VA

5

Self-excited power

AC 0V∽50V/15A

45HZ/55HZ 47.5HZ/52.5HZ

55HZ/65HZ 57.5HZ/62.5HZ

Automatic double frequency

6

Resolving power

tgδ: 0.001%

Cx: 0.001pF

7

Precision

△tgδ:±(Reading*1.0%+0.040%)

△C x :±(Reading*1.0%+1.00PF)

8

measuring range

tgδ

Unlimited

C x

15pF Cx 300nF

 

10KV

Cx 60  nF

 

 5KV

Cx 150 nF

 

 1KV

Cx 300 nF

CVT test

Cx 300 nF

9

CVT range

10∽10000

accuracy

0.1%

Resolving power

0.01

10

Memory size

The 200 group supports U disk data storage

11

Weight

28 Kg

 
Product Pictures
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester

Spare Parts

 
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester
 
Customer feedback
 
Power Factor Meter Transformer Dielectric Loss and Tan Delta Tester
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters