• Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
  • Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
  • Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
  • Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
  • Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
  • Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test

Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Load and No-Load Tester
Type: Transformer Load and No-Load Tester
Accuracy Grade: 0.2
Load Way: Electronic Load
Loading Method: Static Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDBR-P
Display
Digital
Control
Digital Control
Weight
20kg
Power Source
AC220V
Item Name
Transformer Load and No-Load Tester
Test Standard
IEC60076
Function
Transformer No-Load Test,on-Load Test,Capacity Tes
Current Measurement Range
100mA-60A,Accuracy:Class 0.2
Voltage Measurement Range
10V-650V,Accuracy:Class 0.2
Methods
Three Meters Testing Methods
Transport Package
Safety Wooden Packing
Specification
ISO, IEC
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
100sets/Month

Product Description

Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test

Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test

I.Introduction
  1. GDBR-P Transformer on-Load and no-Load Tester can measure transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc.
  2. GDBR-P Transformer on-Load and no-Load Tester is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers.
  3. GDBR-P Transformer on-Load and no-Load Tester is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.

II.Specifications

1. Test items
RMS of three phase voltage: Uab,Ubc,Uca.
Average value of three phase AC voltage: Uab,Ubc,Uca.
RMS of three phase current: Ia,Ib,Ic.
Percentage of No-load loss and No-load current: Po,Io%.
Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.
Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.
Transformer actual capacity and judged capacity.

2. Main technical parameters
Item Name GDBR-P Transformer on-Load and off-Load Tester
Current output 0 ~ 10A
Voltage measurement 0 ~ 10V
Test Capacity 10KV oil-immersed, dry-type transformers: 30KVA ~ 2500KVA
35KV oil-immersed transformers: 50KVA ~ 31500KVA
20KV dry type transformers: 50KVA ~ 2500KVA
35KV dry type transformers: 50KVA ~ 2000KVA
Voltage 0~450V (phase voltage), 0 ~ 800V (line voltage), auto-switch the measurement range
Current 0 ~ 100A, auto-switch the measurement range
Frequency 45Hz ~ 65Hz
Voltage Accuracy  20 ~ 100V, ± 0.2% FS; 100 ~ 450V, ± 0.2%
Current Accuracy 0.5 ~ 10A, ± 0.2% FS; 10 ~ 100A, ± 0.2%
Power Accuracy ± 0.5% (CosΦ> 0.1), ± 1.0% (0.02 <CosΦ <0.1)
Dielectric strength The insulation resistance between voltage, current input terminal and the chassis≥100MΩ.
Between power supply input terminal and the shell can withstand  2KV (rms), for 1 minute
Dimension 400×300×170mm
Weight  6kg (not including test lines)
Working Temperature -5°C~40°C
Working Humidity <95%(25°C)
Altitude <2500m
Power supply 220VAC±10%,45Hz~55Hz.

Transformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
Transformer Load and No-Load Tester for Short Circuit Loss and Capacity TestTransformer Load and No-Load Tester for Short Circuit Loss and Capacity Test
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters