• IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
  • IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
  • IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
  • IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
  • IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
  • IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics

IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics

After-sales Service: All Life Technical Supports
Warranty: 12 Month
Item Name: Tracking Testing Equipment Flammability Analyzer
Application: Flammability Analyzer for Plastics
Standard: IEC 60112
The Electrode Pressure: 1.0 +- 0.05n
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-IEC60112
Electrode Distance
3.99-4.01mm, The Angle 55-65 Degree
Electrode Voltage
100 ~ 600V (48 ~ 60Hz) Adjustable
Dropping Height
for 30 ~ 40mm Adjustable
Dropping Size
44 ~ 55 Drops / 1cm3 Adjustable
Dropping Time
25-35 S
Dropping Times
0 ~ 9999 Times Available
The Testing Process
Automatic Control, Independent Ventilation
The Inside Volume
0.1 M3
The Outside Dimensions
630mm Width X390mm Depth X750mm Height
Manual
Provide
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics

IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics

Introduction:

IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics is in strict accordance with GB4207, IEC60112 standards to design and manufacture. It is suitable for lighting, low-voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, and electrical instruments.

IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics also applies to the insulation, plastic, electrical connectors, and accessories industry. Method for the determination of the proof and the comparative tracking indices of solid insulating materials. IEC60112 Tracking Test Apparatus for Plastics is simple, accurate, reliable, and practical features.

 

Standard:

GB/T4207,GB4706.1 ASTM D 3638-92,IEC60112 ,UL746A

 

Feature:

1.The IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics paint treatment; nice, corrosion-resistant; dimensions: 1200mm X 600mmx 1200mm;

2. All sample holders are made of stainless steel manufacturing;

3. The IEC60112 Tracking Testing Equipment for Plastics consists of a voltmeter, ammeter, time overcurrent relays, power supplies, circuit control system, push button switches, lights, and other components;

4. Automatic drip device includes dropping tube, drip nozzle, counting means counting device drip, drip control device, dropping the volume measuring tools;

5. The drip nozzle device can be adjusted; adjust the height of 30-40mm; ensure the dripping position in the middle of the two electrodes;

6. The electrode means platinum electrode, the electrode fixtures, 4mm gauge, etc., the electrode can be adjusted, and removable;

7. Electrode width 5mm, thickness 2mm, 99.9% purity platinum, 30 to 60 degrees tip;

8. The electrode sample pressure is adjustable, adjustable range (1.00N ± 0.001N); the electrode distance is 4.0mm ± 0.01mm, the angle 60 ° ± 5 °;

9. With the sample stage;

10. With the glass: Thickness ≥4mm;

11. With electrolyte: sodium chloride and alkyl naphthalene sulfonic acid reagent in each bottle.

 

Safety control system:

1. The test voltage: 0 ~ 1000V adjustable; The maximum error of voltmeter displays : 1%;

2. Short-circuit current: (1 Guests 0. 1) A. The voltage drop value does not exceed 10%;

3. The test current exceeds 0.5A duration of more than two seconds, the system automatically shuts down equipment;

4. Security door control system; the door opens, but the test system is not working;

5. The electrode: 5mm × 2mm rectangular platinum electrode and brass electrode of each pair meet size requirements of IEC60112 Figure B.1;

6. The electrode: the angle formed between the electrodes is 60 ° disabilities 5 °, a pitch of (4 Soil 0.1mm);

7. The electrode: the sample pressure: 1 00N disabilities 0.05N;.

8. Drip system: (30 ± 5) seconds (on time 29.8S + open drip duration 0.2S) automatic counting, digital display (can be preset), 50 drops of time: (24.5 Soil 2) min;

9. Drip systems: a drop of the fluid needle tip to the sample surface height: 35mm disabilities 5mm (attach a gauge for measuring your reference);

10. Drip systems: drip Weight: 20 drops: 0.380g ~ 0.489g; 50 drops:.. 0 997g ~ 1 147g;

11. PLC with touch screen control system; to achieve test smarter, more convenient has been operated;

12. The test data is automatically recorded, automatic storage, free retrieval;

 
IEC 60112 Tracking Testing Equipment Flammability Analyzer for PlasticsIEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics

Specification:

Product Name IEC 60112 Tracking Testing Equipment Flammability Analyzer for Plastics
The electrode material electrode tip - platinum metal (platinum)
The electrode pressure 1.0 ± 0.05N
Electrode distance 4.0mm ± 0.01mm, the angle 60 ° ± 5
Electrode voltage 100 ~ 600V (48 ~ 60HZ) adjustable, short-circuit current 1.0 ± 0.1A  of less than 10%v
Dropping height For 30 ~ 40mm adjustable
Dropping size 44 ~ 55 drops / 1cm3 adjustable
Dropping time 30s ± 5s
Dropping times 0 ~ 9999 times available
The outside dimensions 630mm width x390mm depth x750mm heights inside Volume
The inside Volume 0.1 m³ (Can be customized 0.5 m³ or 0.75 m³)

 

Our Services:

*Consulting support 

*Sample testing support

*Factory Visiting

*Training support

*Installation support

*24 Hours &7 days service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now