• Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
  • Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
  • Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
  • Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
  • Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
  • Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832

Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832

After-sales Service: Yes
Warranty: One Year
Modle No.: Gd-En13823
Product: Single Burning Items
Weight: 650kg
Application: Building Materials, Automotive Interiors
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-EN13823
Control Mode
Computer Control
Power Supply
220 V,60 Hz ,20 a
Transport Package
Stndard Wooden Case
Specification
3000 mm (W) x 4500 mm (H) x 3000 mm
Trademark
GOLD
Origin
China
HS Code
9031809090
Production Capacity
10 Sets Single Burning Item /Month

Product Description

Fire Testing With SBI Single Burning Items Of Building Materials

Introduction:
Principle Uses the same principle as the corner fire test and the cone calorimeter
Index Measure changes in oxygen concentration during the test, as well as indicators such as flue gas flow and CO2 concentration in the pipeline
Calculate By calculating the heat release rate at a certain moment, and then measuring the maximum value of the heat release rate and time quotient during the test, that is, the FIGRA index of the heat release rate
Purpose This index is used to classify the flame retardant properties of building materials
Equipment The whole test equipment includes combustion test room, control room, trolley, smoke exhaust pipe, data collection and analysis device, gas supply control device

Advantages:
Structure :
  1. Unit combustion test equipment includes trolley, fixed frame, gas collection hood, collector, J-shaped smoke exhaust pipe, centrifugal fan, wind speed control device, comprehensive measurement section, gas analysis cabinet, data acquisition system, etc.;
  2. Fix the frame, the trolley is pushed into it to carry out the test and support the gas collecting hood, the auxiliary burner is fixed on the frame, and it is equipped with a flame detection system as a flameout protection device;
  3. The stainless steel centrifugal fan can withstand a temperature of 300 degrees, meeting the high temperature requirements of step calibration;
  4. The filter head of the smoke filter is composed of solid PTFE, and the inside is 0.5um filter material;
  5. Compressor type condenser, cooling capacity 320KJ/h, dew point stability 0.1 degrees, dew point static change 0.1K, protection level IP20;
  6. Imported rotameter with a range of 0-5L/min to adjust the intake flow of the analyzer;
  7. A pipeline with a length of 2155mm in the comprehensive measurement area is equipped with pressure probes, three thermocouples, gas sampling probes and white light systems;
  8. The light attenuation system is incandescent type, and is installed on the side pipe of the smoke exhaust pipe with a flexible joint; the 90% response time of the light attenuation system should not exceed 3s;
  9. The lamp is an incandescent lamp and used at a color temperature of (2900±100)K. The power supply is a stable direct current, and the fluctuation range of the current is within ±0.5% (including temperature, short-term and long-term stability);
  10. A lens system for focusing light into a parallel beam of at least 20mm diameter. The light-emitting hole of the photocell should be located at the focal point of the lens in front of it, and its diameter (d) should be determined according to the focal length (f) of the lens so that d/f is less than 0.04;
  11. Air is introduced into the side pipe to keep the optical components clean enough to meet the requirements of light attenuation drift, which can be done by using compressed air.
Lgnition System:
  1. The small trolley can install two mutually perpendicular sample specimens. There is a sand box burner at the bottom of the vertical corner, which adopts the surface ignition method and is equipped with a flame detection system as a flameout protection device;
  2. Mass flow controller, the range is 0g/s-2.5g/s, and the reading accuracy is not less than 1.5%.
Exhaust system:
  1. Stainless steel J-shaped smoke exhaust pipe, a heat-insulated round pipe with an inner diameter of (315±5)mm, and a 50mm-thick high-temperature-resistant mineral wool for heat preservation;
  2. The smoke exhaust system should be able to continuously exhaust smoke at a speed of 0.50m3/s-0.65 m3/s, and be adjusted by frequency conversion;
  3. 3. The gas sampling probe is connected with the gas regulating device and the O2, CO2 inlet gas analyzer.
Gas Sampling System:
  1. The stainless steel gas collecting hood is located on the top of the fixed frame to collect the gas generated by combustion;
  2. The flue gas sampling system consists of a soot filter, a compressor condenser, a drying column, a sampling pump and a peristaltic pump to ensure effective collection of flue gas samples and clean and dry;
  3. Diaphragm pump, flow rate: 400l/h, high temperature and corrosion resistant, used for sampling gas.
Measuring System:
  1. Paramagnetic oxygen analyzer with a range of 0-25%, measuring the oxygen concentration in the gas, the concentration range is 0-25%, T90<12 seconds;
  2. Non-dispersive infrared CO2 analyzer: CO2: 0-10%;
  3. The detector and silicon photodiode probe, the photoelectric detection room has a linear stability of 0.1%, and a 10-bit measurement range. The spectral distribution responsivity of the silicon photodiode is consistent with CIE (illumination curve), and the standard function V(γ) can Achieve at least ±5% accuracy;
  4. Two-way probe, connected to an inlet pressure sensor with a range of at least (0-100) Pa and an accuracy of ±2Pa. The response time for 90% of the output of the pressure sensor is at most 1s.
Control System:
Adjusting the propane flow through the mass flow rate controller should be able to automatically control the gas supply of the burner. The gas mass flow rate is 647mg/s and 2000mg/s. The gas control system can ensure that the change of the gas supply speed during the test should not exceed 5mg/s. Guaranteed output heat 30.7±2kW.

Standard:
BS British Standards Institution BS EN 13823:2010
EN European Standards CSN EN 13501-1+A1:2009, CSN EN 13823+A1:2014
GB Chinese standard GB/T 20284:2006

Specification:
Cart size: 1500mm (W) X 1620mm (D) X 2200mm (H)
Frame size: 1700mm (W) X 2500mm (D) X 2200mm (H)
Weight: 350kg

FAQ:
Q:How to use SBI?
A:The test is carried out in a combustion chamber with a height of 2.4m and an area of 3m X 3m. There is a gas collection hood and a smoke exhaust pipe connected to the sampling pipe on the top of the room, and there is a space for air to flow in and out naturally under the trolley.
During the test, the heat released by the combustion of the sample and the combustion products must be discharged from the exhaust pipe. A comprehensive sampling area is provided in the smoke exhaust duct for placing sensors and sampling pipes. Measure gas temperature, combustion release compound concentration, oxygen concentration, light attenuation of flue gas, total flow of air and combustion products in the sampling pipe.
Q:What are the requirements?
A:The installation needs to meet the following conditions:
  1. Installation height: not less than 5 meters
  2. Floor area: no less than 3m X 3m
  3. Power requirements: 220V, 10A; 380V, 5KW
  4. Ambient temperature: 10°C toz 35°C
  5. Gas Requirements: Propane Gas
  6. Calibration gas: N2, CO2 standard gas
  7. Calibration standard: Heptane
Q:What should be paid attention to in the calibration results?
A:1.The software data calculation is correct, the result is valid, and can provide the following calibration and operation interface:
  1. O2/CO2 analyzer calibration: noise and drift calibration of O2/CO2 output; and results output form
  2. Optical system calibration: noise and drift calibration of flue gas measurement system; and result output form
  3. Optical system calibration: filter calibration; and result output form
  4. Air volume calibration: air volume control range calibration; and result output form
  5. Ladder calibration and result output form
  6. Heptane calibration and result output form
  7. Test program and result output form
2.The burner heat output ladder calibration results meet the following requirements:
  1. The lag time of the O2/CO2 analyzer is not more than 30s;
  2. The response time of the O2/CO2 analyzer is not more than 12s;
  3. The response time of burner switching shall not exceed 12s;
  4. The temperature response time does not exceed 6s;
  5. The ratio q gas 30s (t)/HRR30s (t), (t) should be continuously within (100±5)%;
  6. The difference between the average value of HRR step 2 and the average value of HRR step 3 does not exceed 0.5kW.
3.Heptane calibration results:
  1. The calorific value THR/m of heptane per unit mass should be (4456±222.8) MJ/kg;
  2. The total smoke production TSP/m per unit mass of heptane should be (125±25)m2/kg
Single Burning Items Fire Testing
Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
Single Burning Item Tester
Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
Fire Testing Tester SBI  Single Burning Items
Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832
BS EN 13823 Single Burning Items
Fire Testing Tester Sbi Single Burning Items for Building Materials BS En 13832

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now