Gold Member Since 2007
Audited Supplier
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

Current Transformer Analyzer, Current Transformer Test Equipment, CT Analyzer manufacturer / supplier in China, offering Gdva 405 Portable Current Transformers Analyzer, CT Analyzer, Gd-12579 ASTM D892 Lubrication Oil Foam Performance Tester, ASTM D2872 Asphalt Rolling Thin Film Oven Test Rtfot and so on.

(/ )

Supplier Homepage Product Electrical Testing Equipment Gdva 405 Portable Current Transformers Analyzer, CT Analyzer

Gdva 405 Portable Current Transformers Analyzer, CT Analyzer

FOB Price: US $1 / Set
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1/ Set
Get Latest Price
Production Capacity: 100 Sets/Month CT Analyzers
Transport Package: Standard Wooden Case
Payment Terms: L/C, T/T, D/P, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GDVA 405 CT Analyzer
  • Apparatus: CT Analyzer, Current Transformer Analyzer
  • Test Standard: IEC60044
  • Current Output: 0.001~5A(RMS)
  • Range: 0~10A
  • Turns Ratio Measurement: 1~35000
  • Specification: CE
  • Application: Current Transformer CT Testing Equipment
  • Test Projects: Transformer TTR, Polarity, Knee Voltage etc.
  • Voltage Output: 0.1~180V AC
  • Power Output: 500va
  • Voltage Range: 0~200V
  • Trademark: GOLD
  • Origin: Chongqing of China
Product Description
GDVA 405 Portable Current Transformers Analyzer, CT Analyzer


This Current Transformer Test Equipment ( CT Analyzer ) uses high-performance DSP and ARM, advanced manufacturing process to ensure that the product is stable and reliable, full-featured, high degree of automation, high test efficiency, is the professional testing equipment for the Current transformer and Power Transformer CT / PT industry.
 
Application:

Tests for Current Transformer,CT:
1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement
 
Tests for Voltage Transformer,PT:
1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test
 
CT/PT Analyzer:
1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 PT routine test
 
Analyzer Function and Technical Index:
 
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2 Power supply: AC220V±10%, 50/60Hz±10%
3 Voltage output: 0.1~180V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output: 500VA
6 Maximum knee voltage measurement: 45KV
7 Current measurement:
  Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
  Error: <±0.1%+0.01%FS
8 Voltage measurement:
  Range: 0~200V (automatically change range in 1V/10V/70V/200V)
  Error: < ±0.1%+0.01%FS
9 Turns ratio measurement:
  Range:1~35000
  1~2000     error<0.05%
  2000~5000  error<0.1%
  5000~35000  error<0.2%
10 Phase measurement: error: ±2min; resolution: 0.01min
11 Winding resistance measurement:
   Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
   Error: < 0.2%RDG+0.02%FS
   Maximum resolution: 0.1mΩ
12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden:
   Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
   Error: <0.2%RDG+0.02%FS
   Maximum resolution: 0.001ohm
14 PT Secondary burden:
   Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
   Error :<0.2%RDG+0.02%FS
   Maximum resolution: 0.1ohm
15 PT ratio measurement:
   Range: 1~35000
   1~10000 error<0.1%
   10000~35000 error<0.2%
16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17 PT phase angle measurement: maximum error < 3min
18 Make evaluation for test results according to selected standards
19 Make word report for test result
20 Make word reports one time for multi-group test records on the PC
21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22 Compare excitation curves with saved excitatiocurves in the same window
23 Memory capacity: >1000 groups test results
24 Working condition: temperature: -10ºC~50ºC;

Gdva 405 Portable Current Transformers Analyzer, CT Analyzer
Gdva 405 Portable Current Transformers Analyzer, CT Analyzer
Gdva 405 Portable Current Transformers Analyzer, CT Analyzer


Send your message to this supplier
Avatar
Miss Daisy Tao
Sales
*From:
To: Miss Daisy Tao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now