• ISO 9239 Flooring Radiant Panel Test Equipment for Building Material
  • ISO 9239 Flooring Radiant Panel Test Equipment for Building Material
  • ISO 9239 Flooring Radiant Panel Test Equipment for Building Material
  • ISO 9239 Flooring Radiant Panel Test Equipment for Building Material
  • ISO 9239 Flooring Radiant Panel Test Equipment for Building Material
  • ISO 9239 Flooring Radiant Panel Test Equipment for Building Material

ISO 9239 Flooring Radiant Panel Test Equipment for Building Material

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Exhaust: 30~85m3/Min
Power: AC 220V, 50/60Hz, 20A
Size: 1, 400(W)×500(D)×2, 200(H)mm
Console Size: 600(W)×750(D)×1600(H)mm
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-9239
Weight
200kg
Oversea Training
Available
Transport Package
Standard Wooden Case
Specification
200kg
Trademark
Gold
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
50pieces/Month

Product Description

ISO 9239 Flooring Radiant Panel Test Equipment for Building Material

              ISO 9239 Flooring Radiant Panel Test Equipment for Building Material


Introduction:
This surface of the material spread flame tester (ISO 9239, Flooring Radiant Panel Tester) is test method that formal reflected spread of flame on flooring material back-draft condition when fire on building happened flame at compartment or room adjacent, or high temperature gas radiated to flooring surface a hot radiation heat accumulated at upper of midway during a fire at an early growing step. 
More detail as see the next view; specimen is located at down horizon of 30 degree sloped gas radiation panel per horizon surface. 
Pilot flame as ignition resource put a part edge of specimen on high temperature side. This equipment record ignition time by spark, moving time which flame horizontal pass by specimen of length.


ISO 9239 Flooring Radiant Panel Test Equipment for Building Material

Standard:
• ISO 9239-1:Reaction to Fire Tests for Floorings - Part 1:Determination of the Burning Behavior Using a Radiant Heat Source 
• ISO 9239-2 : Reaction to Fire Tests for Floorings - Part 2 : Determination of Flame Spread at a Heat Flux Level of 25kw/m2. 
• ASTM E 648 : Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source 
• ASTM E 970 : Standard Test Method for Critical Radiant Flux of Exposed at Attic Floor Insulation Using a Radiant Heat Energy Source 
• NFPA 253 : Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source (National Fire Codes, Vol.6) 
• KS F ISO 9239-1 : Reaction to Fire Tests for Floorings - Part 1 : Determination of the Burning Behavior Using a Radiant Heat Source 
• KS F ISO 9239-2: Reaction to Fire Tests for Floorings - Part 2 : Determination of Flame Spread at a Heat Flux Level of 25kw/m2.

Features:

1. The stainless steel test box adopts the front door design to facilitate cleaning the inner wall of the box;

2. The inner wall of the box is calcium silicate plate, which is resistant to high temperature and corrosion;

3. Stainless steel smoke collecting hood device, as for the upper part of the combustion test box;

4. 300mm X 450mm porous ceramic thermal radiation plate, placed at an Angle of 30 °;

5. T-type porous burner is provided, open fire is applied to the sample, and cylinder driving mode is adopted;

6. The optical path system includes a light source of 2900 ± 100 K color temperature incandescent lamp, and the light source is accepted as a silicon photodiode;

7. The shutter is placed in the front of the silicon photodiode, which can be automatically opened and closed by the computer test software for easy calibration;

8. Rotameter regulates the flame height of t-type burner;

9. Propane mass flowmeter regulates gas flow rate of radiant plate and displays it digitally;

10. Provide air source with its own blower and test gas by venturi mixture;

11. Adopt mass flow controller to adjust the inlet flow of radiant plate;

12, SB water cooling heat flow meter, working range is 0-50 kW/m2, heat flow meter accuracy <±2%, response time is 0.2s, provide portable cooling water source, no need for external water;

13. The user can move the heat flux meter to conveniently calibrate the radiant plate heat flux, and the test software can draw the standard heat flux curve;

14. Equipped with foot switch, the user can obtain the flame spread time to reach the test distance according to the flame spread distance, and the computer can record by itself;

15. Install one thermocouple for each chimney and one thermocouple for each box, which can be displayed by computer software;

16. Equipped with infrared radiometer, which can detect the temperature of radiation plate and display it with computer software;

17. Equipped with a 15-inch industrial touch screen computer, the user can monitor the whole combustion test process through the test software;

18. The software can display the values of heat radiation flux, smoke density curve, transmittance curve, wind speed and other relevant test information.
Application:
Building Material
Rail
Car Interior
Other

Specification:
- Steel frame chamber:1400(W)×500(D)×2,220(H) 
- Calcium silicate insulation board 
- Observation window 
- Sliding platform for loading of the test specimen 
- Radiant Panel:300±10mm × 450±10mm (30°, Porous cement) 
- Auto moving ignition burner 
- Scale for check flame spread 
- K-type thermocouples : Range, Ambient ~ 1,500ºC 
- Stainless steel sample holders 
- Dummy calibration panel holders for measuring heat fluxmeter 
- Pyrometer for measuring radiant panel temperature 
- Exhaust duct & hood: Ø 300 / (W)1,700 x (D)1,200 x (H)400 mm 
- Heat Flux Meter 
  Range : 0 ~ 100 ± 10 kw/m2; 
  Surface emissivity : ε=0.95± 0.05; 
- DAQ(Data Acquisition) system 
  NI-PCI DAQ Board; 
  16 Bit wide gain rage, Analog and Digital I/O Board; 
  Three A/D trigger modes; 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters