Gold Member Since 2007
Audited Supplier
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

Fire Resistance Tester, Cable Fire Resistance Tester, Line Fire Resistance Tester manufacturer / supplier in China, offering Line and Cable Fire Resistance Tester, China Manufacturer of Dielectric Loss Tangent Delta Tester, Gd-12579 Lubrication Oil Foaming Characteristics Tester, ASTM D892 Foam Tester and so on.

(/ )

Supplier Homepage Product Fire Testing Equipment Line and Cable Fire Resistance Tester

Line and Cable Fire Resistance Tester

FOB Price: US $1 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1/ Piece
Get Latest Price
Production Capacity: 100 Sets / Month
Transport Package: Wooden Case
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GD-IEC60331A
  • Size: (W) 2,500 * (D) 1,800 * (H)1,600(Test Chamber)
  • Utilities: Propane Gas Valve System
  • Warranty: 12 Months
  • Trademark: GOLD
  • Origin: Chongqing
  • Power: Electronic, AC 220V / 20A
  • Weight: About 100 Kg
  • Standard: IEC 60331
  • Product Name: Line and Cable Fire Resistance Tester
  • Specification: Fire Resistance Tester
  • HS Code: 9013809000
Product Description
Line and cable Fire Resistance Tester

Introduction:

Fire Resistance Tester is used in test conditions where the basic flame temperature is at least 750ºC and

tests the cable exposed to the flame that needs to maintain the circuit integrity.

Standard:

• IEC 60331 

- Test for electric cables under fir conditions - Circuit integrity 

• IEC 60331 Part 11 

- Apparatus - Fire alone at a flame temperature of at least 750˚C 

• IEC 60331 Part 21 

- Procedures and requirements - Cables of rated voltage up to and including 0.6/1kV 

• KWS 409 : Wire of Fire Resistance (Fire-Resistence) - 5.14 Fire resistance test

Specification:

- Test Chamber Size : (W) 1,600 * (D) 500 * (H) 500 

- Heat Source : Ribbon type Propane Gas Burner 

- Burner Dimension : (L) 500 x (W) 10 mm / Space of hole : 3.2mm 

- Flame Failure device, Control thermocouples 

- Pilot feed, Gas flow, Rotameter-type flowmeters 

- Auto Ignition system 

- Mass Flow Controller 

; Gas : 15 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S 

; Air : 180 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S 

- Electric Control : Transformer & Slidacs : 3 Phase 3 wire, 100~1,000V 

- DAQ System 

; 16 channel Analog Input / Output, 200ks/s 

; 16 channel Digital Input / Output 

- Control Rack : (W) 730 x (D) 650 x (H) 1,400 / 19" Rack / Each Assembly Connector

Features:

• The burner has a Ventury Mixer structure and it's a ribbon type propane gas burner with a front length of 500mm 

• Structured with 3 rows of cross holes, Average front width of burner: 15mm, Hole diameter: 1.32mm, Distance between the center: 3.2mm. 

• Allows a polished hole row in pilot hole for flame preservation in both faces of Burner plate 

• A sample support is fixed with a clamp on the side to avoid movement and the other side allows heat spread in length. 

• The central part of the cable is approx. 300mm separated and it's supported by two metal rings. Besides the 2 metal rings there are other ground connected parts. 

• The internal diameter of sample support ring is approx. 150mm made of metal, round shape with a 10±2mm diameter. 

• The front of Burner position is located to be at least 200mm from chamber floor or at least 300mm from chamber's wall surface. 

• The horizontal axis of burner is located 70±10mm downwards from lowest part of sample cable and vertical axis of burner is located approx. 45mm from the vertical axis. 

• Two thermocouple(A,B) are horizontally installed separated 45mm left and right of burner center-line to check if ignition input is within 750+50ºC. 

• Add for KWA 409(Korea Wire Shipbuilding Industry Cooperative) of Fire resistance test(options) 

• It has 2 type of mode which manual mode by control panel and auto mode by computer software. 

Before order, user can select it. It is customizing. And if order IEC 60331-11,12 and BS 6387, user can use one Slidacs system(various up to 1,000V power supplier). Cost should be down.
Send your message to this supplier