Breakdown Voltage Tester, Insulating Oil Breakdown Voltage Tester, Transformer Oil Bdv Test Equipment manufacturer / supplier in China, offering Oil Breakdown Voltage Tester Bdv Testing Instrument, Vacuum Type, Oil Type Circuit Breaker Test Apparatus / Sf6 Type High Voltage Switchgear Tester, Microcomputer Automatic Three Phase Protection Relay Tester and so on.

(/ )

Supplier Homepage Product Electrical Testing Equipment Oil Breakdown Voltage Tester Bdv Testing Instrument

Oil Breakdown Voltage Tester Bdv Testing Instrument

FOB Price: US $1 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1/ Piece
Get Latest Price
Port: Chongqing, China
Production Capacity: 100PCS/Month
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GDYJ-503
  • Test Standard: IEC60156
  • Output Voltage: 2kv/S+-10%
  • Trademark: GOLD
  • Specification: ISO
  • HS Code: 9031809090
  • Function: Oil Breakdown Voltage Tester
  • Feature: Three Vessels Test Kit
  • Maximum Storage Capacity: 50 Groups of Test Data
  • Transport Package: Standard Wooden Case
  • Origin: Chongqing
Product Description
I. Introduction
 
GDYJ-503 Insulation Oil Breakdown Voltage Tester can test three cups of oil at the same time.LCD screen can display test procedure and test result. All the human interaction operations complete by the rotating mouse .
GDYJ-503 Insulation Oil Breakdown Voltage Tester is very easy for customers to measure the breakdown voltage of all kinds of oil. You can print the test result by the micro printer internal the tester. Of course, you can upload the test data to PC from RS232 for data analyzing. The special circuit design makes the tester has a good performance at stability and anti-noise


 II. Application
 
1Breakdown test of user-defined
2Proof test
3Calibration interface for customers
4Uploading data to PC and making word report automatically.
5Result print
 

 III. Technique Index
 
1Output voltageAC 0~80KV
2FeatureThree vessels test at the same time
3Rate of voltage rise2KV/s±10%
4Test error3%RDG+0.3%FS
5Test times setting1-6
6Mixing time setting0~99 second 
7Waiting time setting0-9 minute 59second
8Maximum storage capacity50 groups of test data
9Test standardsIEC60156
10Display256*128 LCD
11Input voltageAC 220V±10% 50Hz/60Hz
12Environment temperature0-50°C    
13Relative humidity≤80%RH
14Size420mm×380mm×410mm  
15Weight28kg