• High Voltage CT PT Evaluation Setup
  • High Voltage CT PT Evaluation Setup
  • High Voltage CT PT Evaluation Setup
  • High Voltage CT PT Evaluation Setup
  • High Voltage CT PT Evaluation Setup
  • High Voltage CT PT Evaluation Setup

High Voltage CT PT Evaluation Setup

After-sales Service: Lifetime Support
Warranty: 1 Year for High Voltage CT PT Evaluation Setup
Type: CT PT Analyzer
Load Way: Electronic Load
Loading Method: Dynamic Load
Display: Digital
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
GDVA-405
Control
Fully Automatic
Weight
15kg
Power Source
AC220V
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Product Name
Current Power Transformer Tester CT PT Analyzer
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
65*46*40CM
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Product Description


High Voltage CT PT Evaluation Setup 
 

High Voltage CT PT Evaluation Setup
The High Voltage CT PT Evaluation Setup is a comprehensive testing and calibration system for current and potential transformers utilized in high voltage substations and switchyards.   

The setup comprises an extensive array of instruments and precision measurement equipment, including a high voltage power supply, turn ratio meter, phase angle meter, multimeter, burden simulator, and digital storage oscilloscope. These devices facilitate the measurement and evaluation of critical parameters such as CT and PT ratios, phase displacement, burden characteristics, polarization index, transient response, and saturation levels under high voltage conditions.   

The system is capable of testing current transformers and potential transformers with primary voltages ranging from 69kV to 765kV, enabling thorough diagnostic assessments of high voltage CTs and PTs in accordance with industry standards and manufacturer specifications.   

Key functions of the evaluation setup:

• Testing of excitation characteristics and turn ratios with an accuracy of ±0.05%   

• Burden testing from 1VA to 1000VA to determine CT loading capability  

• Precision measurement of ratio and phase errors up to ±60 minutes   

• Capture and analysis of transient response waveforms under abnormal conditions

• Identification of saturation at various load levels for optimization of CT performance

By enabling accurate assessment of critical parameters and functions, the High Voltage CT PT Evaluation Setup helps ensure the reliability and safety of high voltage current and potential transformers in utility substations and switchyards. Regular calibration and maintenance assisted by this system can prolong the lifespan of high voltage CTs and PTs while improving the stability and efficiency of high voltage power networks.


 

Detailed Photos

 

High Voltage CT PT Evaluation Setup
High Voltage CT PT Evaluation Setup
 
Product Parameters

High Voltage CT PT Evaluation Setup

 

Certifications

 

High Voltage CT PT Evaluation Setup
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters