• 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
  • 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
  • 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
  • 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
  • 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
  • 0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer

0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Oil Bdv Tester
Type: Transformer Oil Dielectric Strength Tester
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 1800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDYJ-502A
Display
Digital
Control
Fully Automatic
Weight
45kg
Power Source
AC220V
Oil Cylinder Position
Top
Item Name
Transformer Oil Dielectric Strength Tester
Other Name
Transformer Oil Bdv Tester
Function
Determine Bdv of Transformer Oil
Features
Internation Standards for Choice, Automatic
Test Standards
IEC60156, ASTM D877, ASTM D1816, etc.
Printing Function
Yes
Data Updating Function
Yes
Data Storage
100 Groups
Power Supply
220V, 50Hz/60Hz
Warranty Period
1 Year
Transport Package
Plywood Case
Specification
490*410*450mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200 Sets/Month

Product Description

GDYJ-502A 0-100kV Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
 
0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
 

Introduction: 

  • GDYJ-502A Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer is developed according to IEC156 Insulating Oil Dielectric Strength Testing Method;

  • The oil test vessel with temperature measurement unit, so it can detect oil temperature;

  • With 8 Kinds of test mode as optional: IEC156, IS6792, BS5874, ASTM D1816 , ASTM D877, Proof test, 5 minutes standard test, Manual test;

  • It has large LCD display, all the selection can be done by touch panel with color LCD;

  • GDYJ-502A 0-100kv Insulating Oil Bdv Tester also with micro-printer and can store 100 groups data, test data can also be unload to PC and output word report automatically;

  • It is multi-functional, stable, and easy for operation.

 

Specifications:

 
Standards IEC60156/IS6792/BS5874/ASTM D1816/ASTM D877/VDE0370-5
Power supply AC220V± 10%, 50Hz/60Hz
Output voltage AC 0-80KV/0-100KV
Rate of voltage rise 0.5kv/s± 10%, 2kv/s± 10%, 3kv/s± 10%, 5kv/s± 10%
Measurement accuracy ±(1% of full scale + 2 digits)
Test times setting 9
Temperature measurement Yes
Data storage 100 groups
Display 7 inch colorful LCD with touch pad
Pinter Yes
Oil vessel 1
Operating temperature Up to 45 °C,≤80%RH
Size and weight 490*410*450mm,45kg

When do we need to use the Transformer Oil Dielectric Strength Tester?

0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer


1. Routine Maintenance: Transformer oil dielectric strength testing is an essential part of routine maintenance programs for power transformers. Regular testing helps assess the condition of the insulating oil, identify any degradation or contamination, and determine if oil replacement or further maintenance is required.

2. Commissioning of New Transformers: When new transformers are installed, dielectric strength testing of the transformer oil is performed to verify the quality of the insulation and ensure that it meets the required specifications before the transformer is put into service.

3. Periodic Insulation Assessment: Transformer oil dielectric strength testing is conducted periodically to monitor the insulation condition over time. By comparing the results with previous tests, trends can be identified, and any significant changes can be investigated and addressed promptly.

4. Diagnosis of Transformer Issues: If a transformer is experiencing operational issues, dielectric strength testing may be conducted to assess the condition of the insulation. Low dielectric strength readings could indicate problems such as oil degradation, moisture ingress, or the presence of contaminants.

5. Oil Reclamation Processes: Transformer oil reclamation or purification processes involve removing impurities and restoring the dielectric strength of the oil. Dielectric strength testing is used to monitor the effectiveness of the reclamation process and ensure that the oil meets the required standards before being reintroduced into the transformer.



Product Details
 
0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
0-100kv Transformer Oil Dielectric Strength Tester Insulating Oil Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters