Gdva-404 Automatic Current Transformer Tester

FOB Price: US $7 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $7/ Set
Get Latest Price
Port: Chongqing, China
Production Capacity: 100sets/Month
Payment Terms: L/C, T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GDVA-404
  • Trademark: GOLD
  • Specification: ISO, IEC
  • HS Code: 9031809090
  • Item Name: Automatic Current Transformer Tester
  • Transport Package: Safety Wooden Packing
  • Origin: China
Product Description
I. Application
Tests for current transformer:
1)Excitation curve and parameters test
2)Turns ratio test
3)Ratio and phase error test
4)Polarity mark check
5)Coil resistance measurement
6)Secondary loop burden measurement
7)Error line curve test for protection CT
8)Transient CT parameters test
9)CT nameplate guess
10)Saturation hysteresis loop curve measuremen
 
Applications for CT PT tester:
1) CT nameplate check
2) CT parameters check in work burden
3) CT transient parameters analysis
4) CT ratio and phase error calibration
5) PT routine test
 
II. CT PT tester technical index
1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement:45kv
7 Current measurement: 
Range:0~10A (automatically change range in 0.1/0.4/2/10A) 
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~35000,
1~2000 error<0.05%
2000~5000 error>0.1%
5000~35000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement: 
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS 
Maximum resolution 0.001ohm
14 PT Secondary burden: 
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS 
Maximum resolution: 0.1ohm
15 PT ratio measurement:
Range :1~35000,
1~5000 error<0.2%
5000~35000 error<0.5%
16 Saved data groups:>1000groups
17 Work condition: Temperature:-10°C~50°C, moist:≤90%
18 Size: 485mm×356mm×183mm
19 Weight: <15Kg