Basic Info
  • Model NO.: GD-17040
  • Application Field: Petroleum Products, Coal, etc.
  • Xrf Sulfur Analyzer Measurement Range: Sulfur Content From 20ppm~5%
  • Sample Quantity: 2-3ml
  • Packing Size: 51*43*27cm, 54*49*29cm
  • Warranty Period: 1 Year
  • Transport Package: Packed in Veneer Case
  • Origin: Chongqing, China
  • Name: Laboratory Equipment Sulphur Content in Lubricants
  • Xrf Sulfur Analyzer Test Standard: ASTM D4294, GB/T11140, GB/T 17040
  • Xrf Sulfur Analyzer Test Mode: Automatic
  • Price: Competitive
  • Gross Weight: 23kg
  • Trademark: GOLD
  • Specification: Refer to detailed description
  • HS Code: 9031809090
Product Description
GD-17040 Laboratory Equipment Sulphur Content in Lubricants Analysis Equipment
 
 
Specifications:

No.

Parameters

Specifications

1

Measurement range:

7 ppm to 5%

2

Repeatability

<0.029 ( S+0.6)

Reproducibility

<0.063 ( S+0.6)

3

Sample quantity

2~3ml (equal to sample depth of 3~4 mm)

4

Measurement time

60, 120, 240, 300, and 600 s at random

5

Calibration curve numbers

9. 5 of them are linear equation in one unknown and 4 of them are binomial parabola

6

Measurement times

It can set 2, 3, 5, 10, and 50 times at random

7

Working Temperature

5~40 ºC

8

Relative humidity

≤85% (30 ºC)

9

Power supply

AC 220V±20V, 50 Hz

10

Rated power

30 W

11

Size and weight

468 mm*368 mm*136 mm; 13 kg

 
 
Application:
GD-17040 X- ray Fluorescence Sulfur Analyzer can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
 
GD-17040 X- ray Fluorescence Sulfur Analyzer can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
 
GD-17040 X- ray Fluorescence Sulfur Analyzer  can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
 
Introduction:
GD-17040 X- ray Fluorescence Sulfur Analyzer  is specially designed to determine sulfur content in the petroleum products. 
 
Adopts energy-dispersive principle, and with integrated design, it is rapid and accurate. 
 
GD-17040 X- ray Fluorescence Sulfur Analyzer  can meet the requirements of National Standard GB/T 17040 and GB/T11140 on repeat-ability and reproduction, and it can also meet requirements of ASTM D4294-03 on these indexes. 
 
GD-17040 X- ray Fluorescence Sulfur Analyzer  provides a measure to determine sulfur content during petroleum or petrochemical production process.
 
 
 
Characteristics:
Electromechanical integration; microprocessor control; large screen LCD display; Man-machine conversation; simple and beautiful;
 
It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.
 
Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and hydrogen (C/H).
 
It has self-diagnostic function, so it can determine its working state and electric parameters.
 
It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multi-function pressure device, so it is rapid and convenient. It can record sample serial number, S% (m/m), and date.
 
The sample holder can be precisely located. It can move out from inside of the instrument for sample location and anti-leakage parts replacement. It is convenient and it can avoid any contamination to detection system.
 
It can save large quantity of test data. You can browse test data and calibration curve at any time.
 
It uses a thermal printer, so it is easy to replace printing paper. It is needed to speed money on printing ribbon.
 
Equipped with a RS232 serial port, it can connect with any computer or web system.
 
Its safe X-ray protection measures can keep people from injury of X-ray radiation.